Order #: PT9-SYS-1C-1-A-0-SC
Mfg #: PT9-SYS-1C-1-A-0-SC
Panametrics PT9-SYS-1C-1-A-0-SC Portable Ultrasonic Flowmeter, 110/120VAC, 2 to 24" Pipes
Order #: PT9-SYS-1C-1-A-0-SC
Mfg #: PT9-SYS-1C-1-A-0-SC
What’s New About the TransPort PT900?
The PT900 maintains the same high performance as the PT878, but features a total redesign of the fl ow transmitter, clamping fixture and user interface. Key improvements include a redesigned fixture and a streamlined user interface on an Android tablet.
Why Buy the PT900 from Transcat? Inventory. Selection. Price.
TransPort PT900 Makes Your Job So Much Easier
The PT900 has undergone the most involved voice of the user effort to date for GE’s flow products. Several years of learning about how people use portable flow meters and what they want and need while making flow rate measurements have influenced the PT900’s design. GE validated this learning and modified the design approach by sharing initial concepts and early prototypes with users. The result? The best portable flow meter needs to be versatile, easy to install, intuitive to use and capable of making reliable measurements even in the most difficult applications.
Operation and PerformanceFluid TypesLiquids: acoustically conductive fluids, including most clean liquids and many liquids with small amounts of entrained solids or gas bubbles Flow MeasurementPatented Correlation Transit-TimeTM mode Pipe SizesStandard: 0.5 to 24 in. (15 to 600 mm) Optional: up to 300 in. (7500 mm) available upon request Pipe Wall ThicknessUp to 3 in. (76.2 mm) Pipe MaterialAll metals and most plastics Accuracy
Installation assumes a fully developed, symmetrical flow profile (typically 10 pipe diameters upstream and 5 pipe diameters downstream of straight pipe run). Final installation accuracy is a function of multiple factors including fluid, temperature range, pipe centricity among other factors. Repeatability±0.2% of reading Range (Bidirectional)0.1 to 40 ft/s (0.03 to 12.19 m/s) Response TimeUp to 2 Hz Measurement ParametersVelocity, Volume, Mass, Energy, Total Flow Channels1 or 2 channels |
Flow TransmitterEnclosureIP65 rating Specifications
Analog Inputs4-20 mA (qty 2) Analog Output4-20 mA (qty 1) Digital OutputPulse (Totalizer), Frequency, Alarm (qty 1) Digital Communication
Battery
Operating Temperature-20 to 55°C (-4 to 131°F) Electronics Classifications
|
|
User InterfaceDisplayTablet with Android operating system (version 4.4 or greater), LCD capacitive touchscreen, 800 x 1280 resolution Dimensions
Battery Life>12 hours of continuous use Battery Charger100 to 250 VAC (50/60 Hz) Operating Temperature0 to 50°C (32 to 122°F) Communication with Flow TransmitterBluetooth |
Software Application (PT900 APP)Intuitive, Swipe Screen Interface
LanguagesEnglish, Arabic, Chinese (Simplified), Dutch, French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish, Swedish, Turkish Installing the PT900 APPObtain the PT900 APP from:
|
- Panametrics PT900 Energy kit: pair of 4-wire PT 1000 RTDs with transmitterEnergy kit: pair of 4-wire PT 1000 RTDs w/transmitter
Order #: PT9-E
Mfg #: PT9-E
Availability: Ships in 3-4 weeks$2,534.00 - Panametrics PT9-CRR-10-HT Medium Pair C-RR transducers, -40 to 410F, 2" to 24" pipesMedium Pair C-RR transducers, -40 to 410F, 2"to 24" pipes
Order #: PT9-CRR-10-HT
Mfg #: PT9-CRR-10-HT
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT9-CRR-10-NT Medium Pair C-RR transducers, -40 to 302F, 2" to 24"Medium Pair C-RR transducers, -40 to 302F, 2"to 24"
Order #: PT9-CRR-10-NT
Mfg #: PT9-CRR-10-NT
Availability:In stock$2,548.00 - Panametrics PT900 transducer clamping fixture for C-RR transducersPT900 transducer clamping fixtu for C-RR transducers
Order #: PT9-FIXTURE
Mfg #: PT9-FIXTURE
Availability:In stock$1,008.00 - Panametrics PT9-POWER-US 110/120 VAC (NEMA 5-15P) power cord for PT900110/120 VAC (NEMA 5-15P) power cord for PT900
Order #: PT9-POWER-US
Mfg #: PT9-POWER-US
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT900 Standard soft shell carrying case for PT900Standard soft shell carrying case for PT900
Order #: PT9-SOFTCASE
Mfg #: PT9-SOFTCASE
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT9-SD SD card including PT900 tablet app and manualsSD card including PT900 tablet app and manuals
Order #: PT9-SD
Mfg #: PT9-SD
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT9-SUBCONNECT LEMO to BNC adapter connectors at PT900LEMO to BNC adapter connectors at PT900
Order #: PT9-SUBCONNECT
Mfg #: PT9-SUBCONNECT
Availability: Ships in 3-4 weeks$145.60 - Panametrics PT9-CFLP Small Pair CF-LP transducers, -40 to 446F, 0.5" to 2" pipesSmall Pair CF-LP transducers, -40 to 446F, 0.5"to 2" pipes
Order #: PT9-CFLP
Mfg #: PT9-CFLP
Availability:In stock$3,752.00 - Panametrics PT900 Battery charger for spare batteryBattery charger for spare battery, PT900 transmitter
Order #: PT9-CHG
Mfg #: PT9-CHG
Availability: Ships in 3-4 weeks$700.00 - Panametrics PT900 BATTERY Spare Rechargable Battery PT900 TransmitterSpare Rechargable Battery PT900 Transmitter
Order #: PT9-BAT
Mfg #: PT9-BAT
Availability:In stock$840.00 - Panametrics PT9-C48 PT900 Chain assembly mounting, pipe sizes up to 48"PT900 Chain assembly mounting, pipe sizes up to 48"
Order #: PT9-C48
Mfg #: PT9-C48
Availability:In stock$236.60 - Panametrics PT9 Power adapter from line power to PT900 transmitterPower adapter from line power to PT900 transmitter
Order #: PT9-POWERADAPTER
Mfg #: PT9-POWERADAPTER
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT9-BNCADAPT TNC to BNC adapter for C-RS, C-PT, or C-ET transducersTNC to BNC adapter for C-RS, C-PT, or C-ET transducers
Order #: PT9-BNCADAPT
Mfg #: PT9-BNCADAPT
Availability: Ships in 3-4 weeks$154.00 - Panametrics PT9-AIO Analog input and output cable for PT900 transmitterAnalog input and output cable for PT900 transmitter
Order #: PT9-AIO
Mfg #: PT9-AIO
Availability: Ships in 3-4 weeks$301.00 - Panametrics PT9-EXT Pair 100 feet extension cable (for C-RR transducers only)Pair 100 feet extension cable (for C-RR transducers only)
Order #: PT9-EXT
Mfg #: PT9-EXT
Availability:In stock$588.00 - Panametrics PT900 CRTD1000 cable for connecting to PT900 transmitterCRTD1000 cable for connecting to PT900 transmitter
Order #: PT9-CRTD
Mfg #: PT9-CRTD
Availability: Ships in 3-4 weeks$784.00 - Panametrics PT900 Android based touch screen tablet & case for PT900Android based touch screen tablet & case for PT900
Order #: PT9-TABLET-01
Mfg #: PT9-TABLET-01
Availability:In stock$1,162.00 - Panametrics PT9-SPARE Replacement PT900 transmitter with mounting strapsReplacement PT900 transmitter with mounting straps
Order #: PT9-SPARE
Mfg #: PT9-SPARE
Availability: Ships in 3-4 weeks$12,390.00 - Panametrics PT900 Hard sheel carrying case for PT900 PT9-HARDCASEHard sheel carrying case for PT900 PT9-HARDCASE
Order #: PT9-HARDCASE
Mfg #: 128M7072
Availability:In stock$1,316.00 - Panametrics PT9-OD Outer diameter measurement tap (Metric and English units)Outer diameter measurement tap (Metric and English units)
Order #: PT9-OD
Mfg #: PT9-OD
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT900 Stylus for use with PT900 tabletStylus for use with PT900 tablet
Order #: PT9-STYLUS
Mfg #: PT9-STYLUS
Availability: Ships in 3-4 weeks$47.60 - Panametrics PT900 25' transducer cable from C-RR to PT900 transmitter25' transducer cable from C-RR to PT900 transmitter
Order #: PT9-TRANSDUCERCABLE
Mfg #: 101N0321
Availability:In stock$483.00 - Panametrics PT9 Pipe wall thickness gaugePipe wall thickness gauge
Order #: PT9-TG
Mfg #: PT9-TG
Availability: Ships in 3-4 weeks$3,920.00 - Panametrics PT9-CRR-05-NT Large Pair C-RR transducers, -40 to 302F, 6" pipesLarge Pair C-RR transducers, -40 to 302F, 6" pipes
Order #: PT9-CRR-05-NT
Mfg #: PT9-CRR-05-NT
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs. - Panametrics PT9-DIO Digital and discrete input & out cable, PT900 transmitterDigital and discrete input & out cable, PT900 transmitter
Order #: PT9-DIO
Mfg #: PT9-DIO
Availability:This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs.
-
Panametrics PT9-TG for Rent, Pipe Wall Thickness Gauge for PT900Pipe Wall Thickness Gauge for PT900Call for price
-
Panametrics PT9-CRR-10-NT for Rent, Pair of 2 to 24" Transducers for the PT900 with FixturePair of 2 to 24in Transducers for PT900 w/FixtureCall for price
-
Panametrics PT900 PT9-SYS-1C-1-G-0-SC Portable Ultrasonic Flowmeter, 1 channel, 110/120C small/medium TransducerPortable Ultrasonic Flowmeter 1ch 110/120C small/med Trans$19,644.04
-
Panametrics PT9-CFLP for Rent, Pair of 1/2 to 2in Transducers for PT900 with FixturePair of 1/2 to 2in Transducers for PT900 w/FixtureCall for price
-
Panametrics PT9-SYS-2C-1-A-A-SC Portable Ultrasonic Flowmeter, 2 channel, 110/120 VAC C-RR transducerPortable Ultrasonic Flowmeter 2ch 110/120 VAC C-RR transducer$19,768.00
-
Panametrics PT900 for Rent, Portable Liquid Ultrasonic Flowmeter, 2-Channel
Portable Liquid Ultrasonic Flowmeter,2-Channel
Call for price