Order #: RP1002C
Mfg #: RP1002C

Product Highlights
Specifications
Electrical Characteristics
Current Range |
50mV/A, 500mV/A |
DC Accuracy, typical |
500mV/A: ±3% ±20mA (20mA to 14A peak range) 50mV/A: ±4% ±200mA (200mA to 100A peak range) 50mV/A: ±15% maximum (100A peak to 140A peak range) |
Gain versus frequency, typical |
See Appendix 1 Gain versus Frequency at 1 A Peak (Typical) |
Max. Working Current |
SeeVoltage and Current Ratings |
Max. Working Voltage |
SeeVoltage and Current Ratings |
Max. Floating Voltage |
SeeVoltage and Current Ratings |
Frequency Range |
DC to 1MHz (-3dB) |
Battery Type and Life, typical |
9V NEDA 1604A, IEC 6LR61 8 hours (1 each) |
DC Signal Linearity, typical |
See Appendix 3 DC Signal Linearity in 50mV/A Range (Typical) |
Phase versus frequency, typical |
See Appendix 4 Phase versus Frequency at 1 A Peak (Typical) |
Voltage and Current Ratings
Parameter |
Max. Working Current (A) |
Max. Working Voltage (V) |
Max. Floating Voltage (V) |
|
50mV/A Range |
500mV/A Range |
|||
DC |
70[1] |
7 |
600 |
600 |
DC+AC Peak |
70[1] |
7 |
600 |
600 |
AC Peak |
70 |
7 |
600 |
600 |
AC Peak-peak |
140 |
14 |
1200 |
---- |
RMS CAT III |
50 |
5 |
600 |
600 |
RMS CAT II |
50 |
5 |
600 |
600 |
RMS CAT I |
50 |
5 |
600 |
600 |
Physical Characteristics
Dimensions |
262mm x 81mm x 36mm |
Max. Conductor under test Size |
10.3mm |
Dual-BNC Coaxial Cable Length |
100cm |
Weight |
310g (battery excluded) |
Environmental Characteristics
Working Temperature |
0℃ to +50℃ |
Storage Temperature |
-20℃ to +80℃ |
Humidity |
0℃ to +40℃, 95% humidity +40℃ to +50℃, 45% humidity |
Pollution Degree |
2 |
Certifications and Compliances
EC Declaration of Conformity – Low Voltage |
Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC EN 61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements. EN 61010-2-032:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
Additional Compliance |
IEC61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements. IEC61010-2-032:1994: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test. |
Installation (Overvoltage) Category |
CAT III: Equipment in a fixed industrial location (usually permanently connected) CAT II: Equipment at this level includes appliances, portable tools, and similar products. Equipment is usually cord-connected. CAT I: Secondary (signal level) or battery operated circuits of electronic equipment. |