Fluke Calibration 5627A-12-P for Rent, RTD Industrial Probe, -200 to 420C
RTD Industrial Probe 12" x 1/4"OD,-200 to 420C

Order #: 5627A-12-P-RENT1

Mfg #: 5627A-12-P-RENT1

Questions about availability or need help? Contact Us:

(800) 633-0561
Call for price
Call for price

Fluke Calibration 5627A-12-P for Rent, RTD Industrial Probe, -200 to 420C

RTD Industrial Probe 12" x 1/4"OD,-200 to 420C

Order #: 5627A-12-P-RENT1

Mfg #: 5627A-12-P-RENT1

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price
Availability:
In stock
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

The Fluke Calibration 5627A12P Precision Industrial RTD Probe with INFO-CON for 1523/1524, 12 in. x 1/4 in., -200 °C to 420 °C has a temperature range of up to 420 °C and an accuracy as good as ± 0.025 °C. This precision thermometer is shipped with its ITS-90 coefficients and a calibration table in 1 °C increments. One of the best features of the 5627A-12-P sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully.

The 5627A-12-P is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. It is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer with lab code 200706-0.

Transcat Rentals - Rent Equipment from the Industry Leader
   Try Before You Buy
   Save Time & Money
   Weekly and Monthly Rentals
   Access Our Large Inventory
   Long-term Discounts and Rent-to-Buy Options Available

Shop all Rentals

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.

Specifications

Resistance Nominal 100 Ω
Temperature Coefficient 0.00385 Ω/Ω/ °C nominal
Temperature Range ?200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C)
Drift Rate (k=2) ± 0.04 °C at 0 °C after 100 hours at 420 °C
Sheath Material 316 Stainless Steel
Leads PTFE-insulated, nickel-plated stranded copper, 22 AWG
Termination Specify. See Ordering Information.
Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps.
Bending Radius Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
Calibration Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9).
ITS-90 coefficients included.
Immersion At least 100 mm (4 in) recommended
Calibrated Accuracy