Ralston Instruments LC30-GD2M-TX125-00 Pressure/Temperature Gauge, 15 psi, 1/4" M NPT, Probe, Cable
Pressure/Temperature Gauge, 15 psi, 1/4" M NPT, Probe, Cable
Order #: LC30-GD2M-TX125-00
Mfg #: LC30-GD2M-TX125-00
$1,364.73
Ralston Instruments LC30-GD2M-TX125-00 Pressure/Temperature Gauge, 15 psi, 1/4" M NPT, Probe, Cable
Pressure/Temperature Gauge, 15 psi, 1/4" M NPT, Probe, Cable
Order #: LC30-GD2M-TX125-00
Mfg #: LC30-GD2M-TX125-00
Product Highlights
LC30 Pressure / temperature gauge, 15 psi pressure, 1/4" Male NPT back connection, 1/4" Dia x 12" long external probe, 16ft cable
The LC30 is a robust device that measures and displays pressure readings on a large, backlighted screen. It is AC powered with a battery backup. The LC30 has the ability to show High and Low pressure values on-screen, change between 15 different engineering units or add custom engineering units. The included PC FieldLab Desktop software can be used for calibration, testing and logging pressure.
Weight | 12.6 oz / 355 grams |
---|---|
Length | 1.75 in / 45 mm |
Width | 3.4 in / 87 mm |
Height | 4.1 in / 11 cm |
Accuracy - Pressure Measurement | +/- 0.1% of Full Scale (ASME B40.100 Grade 4A/ISO Class 0.1) |
Accuracy - Temperature Measurement | +/- (0.15 +0.002*|t|)°C (IEC 60751 Class A) |
Backup Power | AAA Alkaline (IEC-LR03) |
Battery Count | 2 |
Battery Life | 1000 Hours |
Burst Pressure | 60 PSI / 4.1 bar / 410 kPa |
Calibration Certificate | NIST traceable (included) |
Certifications | Certified to CSA Standard C22.2 No. 61010-1, Complies with Pressure Equipment Directive 2014/68/EU, Complies with Low Voltage Directive 2014/35/EU, Complies with Electromagnetic Compatibility Directive 2014/30/EU |
Country of origin | USA |
Datalogging | PC based (via USB) |
Electrical Connection | M12 female, A Code, Silicone seal, IP67 |
Electrical Rating | 50 mA @ 5 VDC |
Engineering Units | atm, bar, cmH2O @4°C, inH2O @39°C, kPa, mbar, psi, inHg @39°F, kgf / cm^2, mmHg @0°C, mmH2O @4°C, ftH2O @39°F, cmHg @ 0°C, oz / in^2 |
Harmonized Code | 9026.20.0000 |
Ingress Protection | IP67 (1 meter water submersion for 30 minutes) |
LCD Display | 2.4 in / 61 mm segmented LCD Display |
Materials | ABS / Polycarbonate Blend, Powder Coated Aluminum |
Max Operating Temperature | 122 °F / 50 °C |
Max Pressure | 15 PSI / 1 bar / 100 kPa |
Max Probe Temperature | 302 °F / 150 °C |
Max Storage Temperature | 167 °F / 75 °C |
Measurement Type | Gauge Pressure, Temperature |
Media Compatibility | Inert Gas, Natural Gas, Petroleum Based Oil, Water, Air, Alcohol, Antifreeze, Ethylene Glycol, Hydraulic Oil, Mineral Oil, Skydrol, Windshield washer fluid, Transmission fluid, Light motor oil, Ralston Calibration Oil |
Min Operating Temperature | -4 °F / -20 °C |
Min Probe Temperature | -22 °F / -30 °C |
Min Storage Temperature | -40 °F / -40 °C |
Operating Altitude (max) | 10,000 ft (3050 m) |
Panel Mount | Yes |
Power Input | 90-264 VAC, 50-60 Hz |
Primary Power | AC Mains Power |
Process Connection | 1/4" Male NPT |
Process Connection Location | Back mount |
Protection Class | Pollution Degree 2 (UL / IEC 61010-1) |
Relative Humidity | 0% to 90% (-10 to 35°C), 0% to 70% (35 to 50°C) |
Sensor Type | Pressure Sensor |
Temperature Compensation | None |
Temperature Units | °C, °F, K, R |
Thermal Probe | 1/4 in / 6.35 mm diameter, 12 in / 30.5 cm long, external cable, 20 ft / 6.1 m long |
USB Connection | USB (Micro B) |
W1 Radio Installed | No |
Wetted Materials | 316 Stainless Steel |
Wrench Size | 7/8 In / 23 mm |
End 1 Connector | 1/4" Male NPT (ASME B1.20.1) |