Specifications |
T1010 |
T1020 |
IR Resolution |
1024 x 768 (786,432 pixels) |
1024 x 768 (786,432 pixels) |
UltraMax® |
3.14 Mpixels |
3.14 Mpixels |
Thermal Sensitivity/NETD |
<25 mK @ 30°C (86°F) |
<20 mK @ 30°C (86°F) |
Field of View (FOV) |
45° x 34° (21 mm lens), 28° x 21° (36 mm lens), 12° x 9° (83 mm lens) |
45° x 34° (21 mm lens), 28° x 21° (36 mm lens), 12° x 9° (83 mm lens) |
F-Number |
f/1.2 |
f/1.2 |
Lens Identification |
Automatic |
Automatic |
Image Frequency |
30 Hz |
30 Hz |
Focus |
One-shot, manual |
One-shot, manual |
Digital Zoom |
1-8x continuous |
1-8x continuous |
Detector Data |
Detector Type and Pitch
Spectral Range
|
Uncooled microbolometer, 17 µm
7.5 - 14.0 µm
|
Uncooled microbolometer, 17 µm
7.5 - 14.0 µm
|
Image Presentation and Modes |
Display |
4.3", 800 x 480 pixel capacitive touch screen with auto-orientation |
4.3", 800 x 480 pixel capacitive touch screen with auto-orientation |
Viewfinder |
- |
Built-in, 800 x 480 pixels |
Digital Camera |
5 MP with built-in LED |
5 MP with built-in LED |
Color Palettes |
Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava, |
Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava, |
Image Modes |
Infrared, visual, MSX |
Infrared, visual, MSX, Picture-in-Picture |
Picture-in-Picture |
- |
Resizable and movable |
Time-lapse (Infrared) |
- |
15 sec to 24 hrs |
Measurement and Analysis |
Object Temperature Range |
-40°C to 150°C (-40°F to 302°F), 0°C to 650°C (32°F to 1200°F) |
-40°C to 150°C (-40°F to 302°F), 0°C to 650°C (32°F to 1200°F), 300°C to 2000°C (572°F to 3632°F) |
Accuracy |
±2°C (±3.6°F) or ±2% of reading at 25°C (77°F) |
±1°C (±1.8°F) or ±1% at 25°C (77°F) for temperatures from 5°C to 150°C (41°F to 302°F) |
Alarms |
- |
Above, below, interval, moisture, insulation |
Measurement function alarm |
- |
Audible/visible above/below alarms on any selected measurement function |
Compass, GPS |
- |
Yes; automatic GPS image tagging |
METERLiNK® |
- |
Yes; several readings |
Measurement Presets |
No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2 |
No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2 |
Spotmeter |
1 |
10 |
Area |
1 box with max/min/avg |
5 + 5 areas (boxes and circles) with max/min/avg |
Laser Pointer |
Dedicated button |
Dedicated button |
Data Storage and Streaming |
Storage Media |
Removable SD card |
Removable SD card |
Image File Format |
Standard JPEG with measurement data included |
Standard JPEG with measurement data included |
Radiometric IR Video Recording |
- |
Real-time radiometric recording (.csq) |
Non-Radiometric IR or Visual Video |
H.264 to memory card |
H.264 to memory card |
Radiometric IR Video Streaming |
Yes, over USB |
Yes, over USB |
Non-Radiometric IR Video Streaming |
H.264 over USB |
H.264 over Wi-Fi or USB |
Video Out |
- |
HDMI 640 x 480, HDMI 1280 x 720, DVI 640 x 480, DVI 800 x 600 |
Additional Data |
Battery Type |
Rechargeable Li-ion battery |
Rechargeable Li-ion battery |
Battery Operating Time |
Approx. 2.5 hours at 25°C (77°F) ambient temperature and typical use |
Approx. 2.5 hours at 25°C (77°F) ambient temperature and typical use |
Operating Temperature Range |
-15°C to 50°C (5°F to 122°F) |
-15°C to 50°C (5°F to 122°F) |
Storage Temperature Range |
-40°C to 70°C (-40°F to 158°F) |
-40°C to 70°C (-40°F to 158°F) |
Shock/Vibration/Encapsulation; Safety |
25 g / IEC 60068-2-29, 2 g / IEC 60068-2-6, IP 54 /IEC 60529; EN/UL/ CSA/PSE 60950-1 |
25 g / IEC 60068-2-29, 2 g / IEC 60068-2-6, IP 54 /IEC 60529; EN/UL/CSA/PSE 60950-1 |
Tripot Mounting |
UNC 1/4"-20 |
UNC 1/4"-20 |
Weight/Dimensions w/o Lens |
2.1 kg (4.6 lbs), 16.7 x 20.5 x 18.8 cm (6.6 x 8.0 x 7.4 in) |
2.1 kg (4.6 lbs), 16.7 x 20.5 x 18.8 cm (6.6 x 8.0 x 7.4 in) |
Box Contents |
Infrared camera with lens, battery (2 ea) battery charger, neck strap, hard transport case, Bluetooth headset*, lens cap, power supplies, SD card, cables (Std A to Micro-B USB, HDMI to HDMI), FLIR Tools+, printed documentation |