The store will not work correctly when cookies are disabled.
JavaScript seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Javascript in your browser.
Used Fluke 87-5 Industrial True RMS Multimeter
Industrial True RMS Multimeter
Order #: 87-5-USED
Mfg #: 87-5
Availability: Ships in 3-4 weeks
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This item is available as RENTAL at Call for price
Shop now
This item has NEW version starting at
Special Price
$604.74
Regular Price
$720.79
Shop now
Product Highlights
Fluke Model # 87-5
Unique function for accurate voltage and frequency measurements on adjustable speed True-rms ac voltage and current for accurate measurements on non linear signals
Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
Motor drives and other electrically noisy equipment
Measure up to 1000 V ac and dc
Measure up to 10 A (20 A for 30 seconds)
10,000 uF capacitance range
Frequency to 200 kHz and % duty cycle
Peak capture to record transients as fast as 250
Specifications
Voltage DC
Maximum voltage
1000 V
Accuracy
±(0.05% + 1)
Maximum resolution
10 µV
Voltage AC
Maximum voltage
1000 V
Accuracy
±(0.7% + 2) True RMS
AC bandwidth
20 kHz with low pass filter; 3 db @ 1 kHz
Maximum resolution
0.1 mV
Current DC
Maximum amps
10 A (20 A for 30 seconds maximum)
Amps accuracy
±(0.2% + 2)
Maximum resolution
0.01 µA
Current AC
Maximum amps
10 A (20 A for 30 seconds maximum)
Amps accuracy
±(1.0% + 2) True RMS
Maximum resolution
0.1 µA
Resistance
Maximum resistance
50 MΩ
Accuracy
±(0.2% + 1)
Maximum resolution
0.1 Ω
Capacitance
Maximum capacitance
9,999 µF
accuracy
±(1% + 2)
Maximum resolution
0.01 nF
Frequency
Maximum frequency
200 kHz
Accuracy
±(0.005% + 1)
Maximum resolution
0.01 Hz
Duty cycle
Maximum duty cycle
99.90%
Accuracy
±(0.2% per khz + 0.1%)
Maximum resolution
0.10%
Temperature measurement
–200.0°C – 1090°C
–328.0°F – 1994.0°F
excluding probe
80 BK temperature probe
–40.0°C – 260°C
–40.0°F – 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum conductance
60.00 nS
Accuracy
±(1.0% + 10)
Maximum resolution
0.01 nS
Diode
Range
3 V
Resolution
1 mV
Accuracy
±(2% + 1)
Duty cycle range
Accuracy
Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature
–20°C to + 55°C
Storage temperature
–40°C to + 60°C
Humidity (without condensation)
0% – 90% (0°C – 35°C)
0% – 70% (35°C – 55°C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals
UL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size
201 x 98 x 52 mm (with holster)
Weight
355 g
624 g – with holster
Display
Digital
6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog
32 segments, updates 40/sec
Frequency
19,999 counts, updates 3/sec at > 10 Hz
Warranty
Lifetime
Battery Life
Alkaline
~400 hours typical, without backlight
Shock
1 Meter drop per IEC 61010–1:2001
Vibration
Per MIL–PRF–28800 for a Class 2 instrument