Order #: 628
Mfg #: 628
Dwyer Instruments 628 Industrial Pressure Transmitters
Order #: 628
Mfg #: 628
Product Highlights
The Series 626 Industrial Pressure Transmitters possess a highly precise 0.25% full scale accuracy piezo-resistive sensor contained in a compact, rugged, NEMA 4X (IP66) stainless steel general purpose housing or cast aluminum conduit housing. The Series 628 Industrial Pressure Transmitters are ideal for OEMs with 1% full scale accuracy sensors. The corrosion resistant 316L stainless steel wetted parts allow the Series 626 and 628 transmitters to measure the pressure in a multitude of processes from hydraulic oils to chemicals. The Series 626 and 628 are available in absolute and gage pressure ranges with a variety of optional outputs, process connections and electrical terminations to allow you to select the right transmitter for your application.
Features
- Compressors
- Pumping Systems
- Irrigation System Pressure
- Industrial Process Monitoring
- Hydraulic
Service | Compatible gases and liquids |
Wetted Materials | Type 316L SS |
Accuracy | 626: 0.25% FS; 626: 0.20% RSS; 628: 1.0% FS; 628: 0.5% RSS; 626 Absolute Ranges: 0.5% FS; 626 absolute ranges: 0.30% RSS. (Includes linearity, hysteresis, and repeatability.) |
Temperature Limit | 0 to 200°F (-18 to 93°C) |
Compensated Temperature Range | 0 to 175°F (-18 to 79°C) |
Thermal Effect | ±0.02% FS/°F. (includes zero and span) |
Pressure Limits | See table on catalog page |
Power Requirements |
10-30 VDC (for 4-20 mA, 0-5, 1-5, 1-6 VDC outputs); 13-30 VDC (for 0-10, 2-10 VDC outputs); 5 VDC ±0.5 VDC (for 0.5-4.5 VDC ratio-metric output); 10-35 VDC (for 4-20 mA with -CB option); 13-35 VDC or isolated 16-33 VAC (for selectable output with -CB option) |
Output Signal |
4 to 20 mA, 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, or 0.5 to 4.5 VDC; or selectable 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC for -CB option |
Response Time | 300 ms |
Loop Resistance |
0-1000 Ω max. R max = 50 (Vps-10) Ω (4-20 mA output); 5 KΩ min (0-5, 1-5, 0.5-4.5 VDC output); 15 KΩ min (1-6, 0-10, 2-10 VDC output) |
Current Consumption |
38 mA maximum (for 4 to 20 mA output); 10 mA maximum (for 0 to 5, 1 to 5, 1 to 6, 0 to 10, 2 to 10, 0.5 to 4.5 VDC output); 140 mA maximum (for all 626/628/629-CH with optional LED) |
Electrical Connections | Model dependent options: Wire end, Hirschman DIN EN 175801-803-C, Packard, Deutsch, M12 |
Process Connection | Model dependent options: 1/8", 1/4", 1/2" male NPT; 1/4" female NPT; 1/4" male or female BSPT; 1/8" or 1/4" male BSPP ISO 1179; 1/4" female SAE valve depressor |
Enclosure Rating | NEMA 4X (IP66) |
Mounting Orientation | Mount in any position |
Weight | 10 oz (283 g) |
Compliance | CE, Optional: NSF/ANSI 61/372, ANSI/UL 218, ANSI/UL 508, NEPA 20 |