Order #: 754-154-BU
Mfg #: 4816043
Fluke 754/154 BU Documenting Process Calibrator and Calibration Assistant with case
Order #: 754-154-BU
Mfg #: 4816043
Product Highlights
The Fluke 154 bundled with the Fluke 754 offers full HART support for calibration, troubleshooting and commissioning
- Automatically documents test results for upload to software
- Multifunction calibration - mA, Pressure, Temperature, Frequency
- Absolute Maximum Operating Voltage: 0.01% mA
- Multifunction - mA, Pressure, Temperature, Frequency
- Supports multiple software packages including DPCTrack2 and ProCalV5
Fluke 754 Overview
You’re going to love what we’ve done with your calibrator.
The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
The 754 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.
For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
HART Capabilities
The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator.
Fluke 754 Highlights
- Save over $615 with Fluke 754 VIP Kits.
See the 754 VIP Kit now! Save over $615
See the 754 VIP Kit now! Save over $560
See the 754 VIP Kit now! Save over $625
- Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
- Power transmitters during test using loop supply with simultaneous mA measurement
- Measure/source pressure using any of 29 Fluke pressure modules
- Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
- Includes HART communication for adjusting and testing HART smart transmitters.
- Includes the new C799 Field soft case
- Three-year warranty
Each Fluke 754 Includes
- Three sets of stackable test leads
- Three sets of TP220 test probes with three sets of “extended tooth” alligator clips
- Two sets AC280 hook clips
- BP7240 Li-ion battery pack
- BC7240 battery charger
- C799 field soft case
- USB communication cable
- Getting started guide
- Instruction manual on CDROM
- NIST traceable certificate of calibration
- DPCTrack™ 2 sample software
- HART communication cable
The 154 puts HART device configuration at your fingertips. An Android™ based tablet user interface makes HART configuration easy. The external wireless modem allows you to connect the modem to the transmitter being tested so you can communicate to the device remotely. HART transmitters can often be found in confined spaces that are difficult to access, or are out of reach. The Fluke 154 helps reduce the need to stand right next to the device being tested or configured so you can work from a safer, more convenient location.
Fluke 154 Highlights
- Full HART Device Description (DD) of all HART devices
- Configure HART devices
- Perform HART trim on HART devices when used with a Fluke 750, or 720 series calibrator
- Monitor device PV, SV, TV, QV and other measured HART variables
- Quarterly HART DD updates for free
- Convenient wireless connectivity to HART modem
- Easy to use, fast connect and view HART data
- Store HART device configurations
- Long range wireless communication up to 250 feet
- Wireless HART Modem: Includes configurable connection cable that accepts either the hook clips for connecting to wires or the extended tooth alligator clips designed to connect to transmitter connection screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device configuration and testing activities. Rugged enclosure and test lead set designed for process environments
- Store device configurations: Store HART device configurations in ASCII or PDF file configurations.
- HART support: Complete access to all features of the HART device's DD including methods. Meets HART physical layer specification: HCF_SPEC-54
- DD updates: Download free DD updates from Fluke.com for 3-years. Updates available when DD updates released from the HART FieldComm group (approximately four times a year).
- Hard side case: Protects and stores tablet, modem, test leads and connection cable in a lightweight durable tote that is easy to carry.
Each Fluke 154 Includes
- Tablet, tablet charger and USB micro-cable
- Fluke HART App. (installed), HART modem
- USB mini-cable, proof of purchase for product activation
- Hook test clips
- Alligator clips
- Magnetic hanging strap
- Case
- Manual installed on tablet
- Three-year warranty
- Transcat 5353C-GCalibration Labels-Green, Self-Laminating, 1 3/4x5/8"
Order #: 5353C-G
Mfg #: CUSTOM QCC306-GR (QZ0530GR)
Availability:In stockSpecial Price $32.11 Regular Price $33.81 - Fluke C700 Hard Carrying Case for 700 Series CalibratorsHard Carrying Case for 700 Series
Order #: C700
Mfg #: 606928
Availability: Ships in 3-4 weeks$454.99 - Fluke 750 SW DPC/TRACK2 Calibration Management SoftwareCalibration Management Software
Order #: 750SW
Mfg #: 4090343
Availability: Ships in 1-2 weeks$7,252.87 - Fluke AC220 SureGrip Alligator ClipsSureGrip Alligator Clips
Order #: AC20
Mfg #: 1610103
Availability:In stockSpecial Price $73.36 Regular Price $88.39 - Fluke BP7240 HZM Li-ion Battery Pack for Fluke 753 and 754HZM Li-ion Battery Pack for Fluke 753 and 754
Order #: BP7240
Mfg #: 4022220
Availability:In stockSpecial Price $297.99 Regular Price $359.03 - Fluke 80PK-22 SureGrip Immersion Temperature ProbeSureGrip Immersion Temperature Probe
Order #: 80PK-22
Mfg #: 2098684
Availability:In stockSpecial Price $160.28 Regular Price $193.11 - Fluke TP74 Test Lead Accessory Set, Lantern Tip Test Probe, Red/BlackTest Lead Accessory Set, Lantern Tip Test Probe,Red/Blk
Order #: TP74
Mfg #: 1541649
Availability:In stockSpecial Price $34.98 Regular Price $42.15 - Fluke 700PCK Pressure Module Calibration KitPressure Module Calibration Kit
Order #: 700PCK
Mfg #: 100062
Availability:In stock$2,551.35 - Fluke 700PMP Hand Pressure Pump, 150 psi, 1000 kPaHand Pressure Pump, 150 psi, 1000 kPa
Order #: 700PMP
Mfg #: 617131
Availability:In stockSpecial Price $760.80 Regular Price $916.63 - Fluke 80PK-9 Type K Lance Tip Probe, T/C Assembly, Molded Plug, 1mType K Lance Tip Probe, T/C Assembly,Moldd.Plug,1m,Bulk
Order #: 80PK-9
Mfg #: 1288229
Availability:In stockSpecial Price $118.51 Regular Price $142.79 - Fluke 700PTP-1 Pneumatic Test Pump, -13 to 600PSIPneumatic Test Pump, -13 to 600PSI
Order #: 700PTP-1
Mfg #: 2811774
Availability: Ships in 3-4 weeks$1,440.23 - Fluke 750P Series Pressure ModulesConfigure your Fluke 750 Series Pressure Module today!
Order #: 750P
Mfg #: 750P
Availability:In stock$2,296.75
Measurement Accuracy
Range/Resolution | 1 Year | 2 Years | |||
---|---|---|---|---|---|
Voltage DC | 100.000 mV | 0.02% + 0.005 mV | 0.03% + 0.005 mV | ||
3.00000 V | 0.02% + 0.00005 V | 0.03% + 0.00005 V | |||
30.0000 V | 0.02% + 0.0005 V | 0.03% + 0.0005 V | |||
300.00 V | 0.05% + 0.05 V | 0.07% + 0.05 V | |||
Voltage AC | 3.000 V (40 Hz to 500 Hz) / 0.001 V | 0.5% + 0.002 V | 1.0% + 0.004 V | ||
30.00 V (40 Hz to 500 Hz) / 0.01 V | 0.5% + 0.02 V | 1.0% + 0.04 V | |||
300.0 V (40 Hz to 500 Hz) / 0.1 V | 0.5% + 0.2 V | 1.0% + 0.2 V | |||
Current DC | 30.000 mA | 0.01% + 5 uA | 0.015% + 7 uA | ||
110.00 mA | 0.01% + 20 uA | 0.015% + 30 uA | |||
Resistance | 10.000 Ω | 0.05% + 50 mΩ | 0.07% + 70 mΩ | ||
100.00 Ω | 0.05% + 50 mΩ | 0.07% + 70 mΩ | |||
1.0000 kΩ | 0.05% + 500 mΩ | 0.07% + 0.5 Ω | |||
10.000 kΩ | 0.1% + 10 Ω | 0.15% + 15 Ω | |||
Frequency | 1.00 to 110.00 Hz / 0.01 Hz | 0.05 Hz | |||
110.1 to 1100.0 Hz / 0.1 Hz | 0.5 Hz | ||||
1.101 to 11.000 kHz / 0.001 kHz | 0.005 kHz | ||||
11.01 to 50.00 kHz / 0.01 kHz | 0.05 kHz |
Source Accuracy
1 Year | 2 Years | ||||
---|---|---|---|---|---|
Voltage DC | 100.000 mV | 0.01% + 0.005 mV | 0.015% + 0.005 mV | ||
1.00000 V | 0.01% + 0.00005 V | 0.015% + 0.0005 V | |||
15.0000 V | 0.01% + 0.0005 V | 0.015% + 0.0005 V | |||
Current DC | 22.000 mA (source) | 0.01% + 0.003 mA | 0.02% + 0.003 mA | ||
Current sink (simulate) | 0.02% + 0.007 mA | 0.04% + 0.007 mA | |||
Resistance | 10.000 Ω | 0.01% + 10 mΩ | 0.015% + 15 mΩ | ||
100.00 Ω | 0.01% + 20 mΩ | 0.015% + 30 mΩ | |||
1.0000 kΩ | 0.02% + 0.2 Ω | 0.03% + 0.3 Ω | |||
10.000 kΩ | 0.02% + 3 Ω | 0.03% + 5 Ω | |||
Frequency | 0.1 to 10.99 Hz | 0.01 Hz | |||
0.01 to 10.99 Hz | 0.01 Hz | ||||
11.00 to 109.99 Hz | 0.1 Hz | ||||
110.0 to 1099.9 Hz | 0.1 Hz | ||||
1.100 to 21.999 kHz | 0.002 kHz | ||||
22.000 to 50.000 kHz | 0.005 kHz |
Technical Data
Data log functions | Measure functions | Voltage, current, resistance, frequency, temperature, pressure | |||
Reading rate | 1, 2, 5, 10, 20, 30, or 60 readings/minute | ||||
Maximum record length | 8000 readings (7980 for 30 or 60 readings/minute) | ||||
Ramp functions | Source functions | Voltage, current, resistance, frequency, temperature | |||
Rate | 4 steps/second | ||||
Trip detect | Continuity or voltage (continuity detection not available when sourcing current) | ||||
Loop power function | Voltage | Selectable, 26 V | |||
Accuracy | 10%, 18 V minimum at 22 mA | ||||
Maximum current | 25 mA, short circuit protected | ||||
Maximum input voltage | 50 V DC | ||||
Step functions | Source functions | Voltage, current, resistance, frequency, temperature | |||
Manual step | Selectable step, change with arrow buttons | ||||
Autostep | Fully programmable for function, start delay, stepvalue, time per step, repeat |
Environmental Specifications
Operating temperature | -10°C to +50°C | ||||
Storage temperature | -20°C to +60°C | ||||
Dust/water resistance | Meets IP52, IEC 529 | ||||
Operating altitude | 3000 m above mean sea level (9842 ft) |
Safety Specifications
Agency approvals | CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 |
Mechanical and General Specifications
Size | 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) | ||||
Weight | 1.2 kg (2.7 lb) | ||||
Batteries | Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh | ||||
Battery life | >8 hours typical | ||||
Battery replacement | Replace without opening calibrator; no tools required | ||||
Side port connections | Pressure module connector | ||||
USB Connector to interface to your PC | |||||
Digital instrument (HART) connector | |||||
Connection for optional battery charger/eliminator | |||||
Data storage capacity | 1 week of calibration procedures results | ||||
90 day specifications | The standard specification interval for the 750 Seriesare 1 and 2 years. | ||||
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2. | |||||
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant. |
Temperature, Resistance Temperature Detectors
Degrees or % of reading - Type (α) | Range °C | Measure °C1 | |||
1 year | 2 year | ||||
100 Ω Pt (385) | -200 to 100 | 0.07°C | 0.14°C | ||
100 to 800 | 0.02% + 0.05°C | 0.04% + 0.10°C | |||
200 Ω Pt (385) | -200 to 100 | 0.07°C | 0.14°C | ||
100 to 630 | 0.02% + 0.05°C | 0.04% + 0.10°C | |||
500 Ω Pt (385) | -200 to 100 | 0.07°C | 0.14°C | ||
100 to 630 | 0.02% + 0.05°C | 0.04% + 0.10°C | |||
1000 Ω Pt (385) | -200 to 100 | 0.07°C | 0.14°C | ||
100 to 630 | 0.02% + 0.05°C | 0.04% + 0.10°C | |||
100 Ω Pt (3916) | -200 to 100 | 0.07°C | 0.14°C | ||
100 to 630 | 0.02% + 0.05°C | 0.04% + 0.10°C | |||
100 Ω Pt (3926) | -200 to 100 | 0.08°C | 0.16°C | ||
100 to 630 | 0.02% + 0.06°C | 0.04% + 0.12°C | |||
10 Ω Cu (427) | -100 to 260 | 0.2°C | 0.4°C | ||
120 Ω Ni (672) | -80 to 260 | 0.1°C | 0.2°C | ||
Source current | Source °C | Allowable current2 | |||
1 year | 2 year | ||||
1 mA | 0.05°C | 0.10°C | 0.1 mA to 10 mA | ||
0.0125% + 0.04°C | 0.025% + 0.08°C | ||||
500 μA | 0.06°C | 0.12°C | 0.1 mA to 1 mA | ||
0.017% + 0.05°C | 0.034% + 0.10°C | ||||
250 μA | 0.06°C | 0.12°C | 0.1 mA to 1 mA | ||
0.017% + 0.05°C | 0.034% + 0.10°C | ||||
150 μA | 0.06 C | 0.12 C | 0.1 mA to 1 mA | ||
0.017% + 0.05°C | 0.034% + 0.10°C | ||||
1 mA | 0.05°C | 0.10°C | 0.1 mA to 10 mA | ||
0.0125% + 0.04°C | 0.025% + 0.08°C | ||||
1 mA | 0.05°C | 0.10°C | 0.1 mA to 10 mA | ||
0.0125% + 0.04°C | 0.025% + 0.08°C | ||||
3 mA | 0.2°C | 0.4°C | 0.1 mA to 10 mA | ||
1 mA | 0.04°C | 0.08°C | 0.1 mA to 10 mA | ||
1. For two and three-wire RTD measurements, add 0.4°C to the specifications. | |||||
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms |
Temperature, Thermocouples
Type | Source °C | Measure °C | Source °C | ||
1 year | 2 years | 1 year | 2 years | ||
E | -250 to -200 | 1.3 | 2 | 0.6 | 0.9 |
-200 to -100 | 0.5 | 0.8 | 0.3 | 0.4 | |
-100 to 600 | 0.3 | 0.4 | 0.3 | 0.4 | |
600 to 1000 | 0.4 | 0.6 | 0.2 | 0.3 | |
N | -200 to -100 | 1.0 | 1.5 | 0.6 | 0.9 |
-100 to 900 | 0.5 | 0.8 | 0.5 | 0.8 | |
900 to 1300 | 0.6 | 0.9 | 0.3 | 0.4 | |
J | -210 to -100 | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800 | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 1200 | 0.5 | 0.8 | 0.3 | 0.3 | |
K | -200 to -100 | 0.7 | 1 | 0.4 | 0.6 |
-100 to 400 | 0.3 | 0.4 | 0.3 | 0.4 | |
400 to 1200 | 0.5 | 0.8 | 0.3 | 0.4 | |
1200 to 1372 | 0.7 | 1 | 0.3 | 0.4 | |
T | -250 to -200 | 1.7 | 2.5 | 0.9 | 1.4 |
-200 to 0 | 0.6 | 0.9 | 0.4 | 0.6 | |
0 to 400 | 0.3 | 0.4 | 0.3 | 0.4 | |
B | 600 to 800 | 1.3 | 2 | 1 | 1.5 |
800 to 1000 | 1 | 1.5 | 0.8 | 1.2 | |
1000 to 1820 | 0.9 | 1.3 | 0.8 | 1.2 | |
R | -20 to 0 | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 100 | 1.5 | 2.2 | 1.1 | 1.7 | |
100 to 1767 | 1 | 1.5 | 0.9 | 1.4 | |
S | -20 to 0 | 2.3 | 2.8 | 1.2 | 1.8 |
0 to 200 | 1.5 | 2.1 | 1.1 | 1.7 | |
200 to 1400 | 0.9 | 1.4 | 0.9 | 1.4 | |
1400 to 1767 | 1.1 | 1.7 | 1 | 1.5 | |
C | 0 to 800 | 0.6 | 0.9 | 0.6 | 0.9 |
800 to 1200 | 0.8 | 1.2 | 0.7 | 1 | |
1200 to 1800 | 1.1 | 1.6 | 0.9 | 1.4 | |
1800 to 2316 | 2 | 3 | 1.3 | 2 | |
L | -200 to -100 | 0.6 | 0.9 | 0.3 | 0.4 |
-100 to 800 | 0.3 | 0.4 | 0.2 | 0.3 | |
800 to 900 | 0.5 | 0.8 | 0.2 | 0.3 | |
U | -200 to 0 | 0.6 | 0.9 | 0.4 | 0.6 |
0 to 600 | 0.3 | 0.4 | 0.3 | 0.4 | |
BP | 0 to 1000 | 1 | 1.5 | 0.4 | 0.6 |
1000 to 2000 | 1.6 | 2.4 | 0.6 | 0.9 | |
2000 to 2500 | 2 | 3 | 0.8 | 1.2 | |
XK | -200 to 300 | 0.2 | 0.3 | 0.2 | 0.5 |
300 to 800 | 0.4 | 0.6 | 0.3 | 0.6 |