The Fluke Networks CFP-Q-ADD is a CertiFiber Pro QUAD. This item should be ordered when you need a CertiFiber Pro Quad (SingleMode and MultiMode) optical fiber certification add-on kit with modules and accessories, WITHOUT a mainframe or remote unit (upgrading from DSX-5000).
Availability:Ships in 3-4 weeks
This product is available for shipping to the United States only.
The Fluke Networks CFP-Q-ADD is a CertiFiber Pro QUAD. This item should be ordered when you need a CertiFiber Pro Quad (SingleMode and MultiMode) optical fiber certification add-on kit with modules and accessories, WITHOUT a mainframe or remote unit (upgrading from DSX-5000).
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type
InGaAs
Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 _W (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 _m and NA = 0.14 for 9/125 _m. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.
Loss/Length Specifications
Specification
CertiFiber Pro Multimode Modules
CertiFiber Pro Singlemode Modules
Testing Speeds (excludes referencing times)
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
1. At the output of the EF-TRC 2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor 3. Relative to power level after 15 minute warm up – at constant temperature
Loss/Length Specifications (continued)
Source Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 _W (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 _m and NA = 0.14 for 9/125 _m. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5-minute warm-up.