Fluke FEV100/TY1 & TSL Test Adapter EV Charging with Type 1 & Tesla Type Plug, US
Test Adapter EV Charging w/ Type 1 & Tesla Type Plug, US
Order #: FEV100-TY1-TSL
Mfg #: 5348051
$2,266.65
Fluke FEV100/TY1 & TSL Test Adapter EV Charging with Type 1 & Tesla Type Plug, US
Test Adapter EV Charging w/ Type 1 & Tesla Type Plug, US
Order #: FEV100-TY1-TSL
Mfg #: 5348051
$2,266.65
Availability: Ships in 3-4 weeks
Product Highlights
Fluke FEV100/TY1 & TSL is the first Fluke product for the electric vehicle charging segment. This product comes with Type 1 and Tesla type connectors. It is designed to test function and safety of electric vehicles charging stations, recommended to comply with SAE-J1772 standards for US stations. Provides critical protective ground testing of the station, GFCI troubleshooting and CP communication stages between vehicle and station.
- The Fluke FEV100/TY1 & TSL is an adaptor with Type 1 and Tesla type connector that simulates the presence of an electrical vehicle to test the functionality and safety of an electric vehicle AC charging station.
- Check that an electric vehicle charging station is correctly wired and that protective earth is functioning properly with the PE pre-test feature.
- Perform GFCI troubleshooting of an electric vehicle charging station and verify it is functioning properly for safety.
- Test different charging states of an electric vehicle charging station with the turn of a button. Verify the charging voltage using a digital multimeter.
Key Attributes
- CP State Simulation: A: ± 12V 1kHz; B: 2.74kϛ +9 V / -12V 1kHz; C: 882ϛ +6 V / -12V 1kHz; D: 246ϛ +3V / -12V 1kHz
- Output voltage : Max. 250 V / 60 Hz, CAT II 300 V
- Compatibility with other test and measurement tools : Digital multimeter, oscilloscope
- Safety Testing : Protective grounding test (PE), GFCI test
Key Uses of this Product
- Simulates electric vehicle and vehicle faults
- Adapter paired with test and measurement tools
- Tests mains supply and grounding
- Tests GFCI ground fault circuit interrupter
Each Unit Includes
- FEV100
- Fluke FEV100/BASIC Test Adapter
- Fluke FEV-CON/TY1 Type 1 Connector & Cable
- Soft Carrying Case
- User Manual
- 3-year warranty
- Fluke FEV-CON-TSL Tesla Type Plug For Test Adapter EV Charging, USTesla Type Plug For Test Adapter EV Charging, US
Order #: FEV-CON-TSL
Mfg #: 5348145
Availability: Ships in 3-4 weeksSpecial Price $575.45 Regular Price $693.32
General specifications | |
Input voltage | UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal |
EV connector | SAE J1772 socket (type 1, 5P single-phase) Connector for Tesla™ station |
Internal power consumption | 2 W max. |
Operating temperature | -4 °F to 104 °F (-20 °C to 40 °C) |
Storage temperature | -4 °F to 122 °F (-20 °C to 50 °C) |
Operating humidity range | 10 % to 85 % relative humidity non-condensing |
Storage relative humidity | 0 % to 85 % non-condensing |
Operating altitude | 6561 ft (2000 m) max. |
Dimensions (H x W x D) | Approx. 8.66 x 4.33 x 1.77 in (220 x 110 x 45 mm) without cable assembly |
Weight | Approx. 4.4 lb (2 kg) |
Safety standards | IEC 61010-1, Pollution Degree 2 |
IEC 61010-2-030 | |
Measurement category | CAT II 250 V |
IP protection class | IP54 |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Basic Electromagnetic Environment |
CISPR 11: Group 1, Class A | |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | |
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Functions | |
CP States | A, B, C, D |
CP Error "E" | On/off |
PE Error | On/off |
GFCI Test | Yes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms |
PE Pre-Test (typical) | Visible indication >30 V on PE conductor |
Outputs (for test purpose only) | |
Measuring terminals | Max. 250 V 50/60 Hz, CAT II 250 V |
L1, L2/N, PE | |
CP signal output terminals | Approx. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE |