Fluke Calibration 5609-9BND-A Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for the 914X
Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for 914X

Order #: 5609-9BND-A

Mfg #: 3116028

Questions about availability or need help? Contact Us:

(800) 633-0561
$2,833.60

Fluke Calibration 5609-9BND-A Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for the 914X

Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for 914X

Order #: 5609-9BND-A

Mfg #: 3116028

$2,833.60
Availability: Ships in 3-4 weeks

Choose Your Options:

Add Calibration

You have chosen to add the following Calibration Services to Your Order

Make sure your instrument is calibrated and ready to use the minute you open the box by adding our expert calibration service. Why Calibrate? For a complete descriptions of Transcat Service Levels, click here.

Already have this this item and need calibration? Request a calibration quote

This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

  • -200 to 670 °C
  • If you want a very stable thermometer from -200 °C to 670 °C and are particular about the calibration, then look no further than our 5609 Secondary Reference PRT
  • Its short-term stability at the triple point of water is only ± 10 mK and its one-quarter inch (6.23 mm) diameter lets you get accurate measurements in only 100 mm of immersion
  • With multiple sheath length options on both of these probes, and an optonal 90 ° bend at nine inches from the tip for dry-well applications, you can find the dimensions that are just right for your specific application
  • The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm
  • When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem
  • Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range
  • The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts

Webinars

Automating and Documenting Temperature Calibration Webinar with Fluke Calibration

Differential Pressure Meter Gas Custody Transfer Calibration Webinar with Fluke

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
All products in this series