Order #: 772
Mfg #: 3362352
Fluke 772 Milliamp Clamp Meter
Order #: 772
Mfg #: 3362352
The Fluke 772 Milliamp Process Clamp Meter with Integrated mA Loop can measure mA signals without breaking the loop. The Fluke 772 mA Clamp Meter expand upon the capabilities of the popular 771 mA Clamp Meter, adding loop power and mA sourcing to the troubleshooting and process calibration capabilities in all Fluke mA clamp meters. If you are spending time taking mA measurements by removing a wire and breaking the loop, calling the control room to isolate a loop, testing analog input/output on a console, troubleshooting devices with mA inputs and outputs, repairing intermittent or erratic 420 mA loops, going back to the shop to get extra tools then you need to take a good look at the Fluke 772 mA Clamp Meter.
Fluke 772 Highlights
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 772 mA Clamp Meters. It's designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Fluke 772 Features
- Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
Each Fluke 772 Includes
- Soft carrying case
- Test leads
- Alligator clips
- Hanging strap
- User’s manual
Webinars
- Transcat 5353C-GCalibration Labels-Green, Self-Laminating, 1 3/4x5/8"
Order #: 5353C-G
Mfg #: CUSTOM QCC306-GR (QZ0530GR)
Availability:In stockSpecial Price $32.11 Regular Price $33.81
Specifications | ||
Diameter of measurable conductor | 0.177” or 4.5 mm max | |
Operating temperature | -10 to 50ºC | |
Storage temperature | -25 to 60ºC | |
Operating humidity | < 90% @ <30ºC, < 75% @ 30 to 55ºC | |
Operating altitude | 0 to 2000 m | |
IP rating | IP 40 | |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) | |
Weight | 410 g, (14.4 oz) | |
Vibration | Random 2 g, 5 to 500 Hz | |
Shock | 1 meter drop test (except the jaw) | |
EMI/RFI | Meets EN61326-1 | |
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. | ||
Temperature coefficient | 0.01% ºC | |
(< 18ºC or > 28ºC) | ||
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms | |
Warranty | Three years for electronics | |
One year for cable and clamp assembly | ||
Functional Specifications | ||
mA measurement | Resolution / range | 0 to 20.99 mA |
(measured by clamp) | Accuracy | 0.2% + 2 counts |
Resolution / range | 21.0mA to 100.0 mA | |
Accuracy | 1% + 5 counts | |
mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts |
Visit our Fluke Loop Calibrator Selection Guide
-
Fluke 771 Milliamp Process Clamp MeterMilliamp Process Clamp MeterSpecial Price $1,221.16 Regular Price $1,327.35
-