Product Highlights

The Fluke 1773 is a dual-purpose power quality troubleshooter and logger. It measures the fundamental power quality variables required to measurement the overall power quality health of your electrical system. The user interface is optimized to make the process of data capture as simple and reliable as possible with the inclusion of instrument powering from the measurement circuit, automatic connection check and correction.

Key Attributes

  • Measurement Category 600V CAT IV/1000V CAT III
  • Power: Includes associate variables and assocciated variable including apparent power, kvar, energy reactive energy, power factor, cos Φ, etc. all according to IEEE1460
  • Wide range of power quality variables.
  • Includes dips and swells, unbalance, harmonics to 50 harmoncs, 2-9kHz and up to 30kHz, flicker and inrush
  • Automated logging of variables.
  • Over 500 of the most frequently used variables with automated setup or this can be expanded with additional values. Values are logged with 1s to 30 minute average times. Dips, swells and transients occur in much shorter times and are recorded at much higher speed indendently of the logging average.

Key Uses of the Product

  • Measure power quality according to the most stringent IEC61000-4-30 Class A requirement.
  • Capture dips, swells and interruptions.
  • Perform harmonic studies to discover the effects of disturbing loads on your network
  • Discover the sources of nergy loses and waste in your facility.

HIGHER HARMONICS: The need to measure harmonics above the 50th has become increasingly importnant as more disturbing harmonic loads are added to the newwork such as inverters supplying power and motor drives consuming power. The 1770 series measure harmonics up to 30kHz

AUTOMATICALLY MEASURE POWER AND POWER QUALITY PARAMETERS

Critical power quality data is captured as soon as you begin a session, without extensive setup or selections

INTUITIVE USER INTERFACE

The streamlined user interface makes it easy to navigate between measurement parameters like V/A/Hz, power, dips and swells, harmonics, or power quality health at the push of a button

HIGH-SPEED VOLTAGE TRANSIENT CAPTURE

Capture damaging high-speed transients so you can mitigate their effects before equipment fails

ANALYSIS AND REPORTING

Comes standard with Fluke Energy Analyze Plus software giving you the ability to create customized reports, or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519 and GOST 33073

Automatic measurements. More flexibility. Better power quality troubleshooting.

Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. With the 1770 Series you'll never miss a critical power quality event-from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.

Automatic measurement capture

Whether you're performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you're collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you're working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.

Ultimate measurement confidence

The Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer-in a single, easy-to-use, handheld device. The 'PQ Meter' function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed 'PQ Logging and Analysis' function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you're capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement-even if you were unsure about what to look for when you started.

  • NEW Firmware updateTimezone database updated to reflect recent important changes.
  • Automatically measure power and power quality parameters
  • At-a-glance power quality health for faster troubleshooting
  • Easily view V/A/Hz, power, dips, swells, and harmonics data
  • Capture high-speed transients up to 8 kV
  • Power directly from measurement circuit without a line cord

Each Unit Includes

  • FLUKE-1773 Power Quality Analyzer
  • FLUKE-17XX flat cable voltage test lead 3-phase+N
  • AC285 black alligator clips (set of four)
  • AC285 green alligator clip
  • Black 1M USB-C cable
  • Line cords (US, EU, UK, AUS, BRA)
  • FLK-17XX 0.18M test lead set
  • Green test lead
  • Cable marker set (for voltage and current)
  • FLUKE-174X-MA-C8 wall outlet adapter
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
  1. Fluke 5263915 Antenna Cable,5M, 50Ohms, 6Ghz
    Fluke 5263915 Antenna Cable, 5M, 50Ohms, 6Ghz
    Antenna Cable,5M, 50Ohms, 6Ghz

    Order #: 5263915

    Mfg #: 5263915

    Availability: Ships in 3-4 weeks
    Special Price $686.30 Regular Price $826.87
  2. Fluke 177X LI-ION BATTERY 177X Li-Ion Battery, Bp177X 3.56V, 4000Mah
    Fluke 177X Li-Ion Battery, 3.56V, 4000Mah
    177X Li-Ion Battery, Bp177X 3.56V, 4000Mah

    Order #: 177X-LI-ION-BATTERY

    Mfg #: 5272862

    Availability: Ships in 3-4 weeks
    Special Price $161.41 Regular Price $194.47
  3. Fluke 17XX CABLE MARKER SET 17Xx Cable Marker Set, 05Mm, (Color)
    Fluke 17XX Cable Marker Set
    17Xx Cable Marker Set, 05Mm, (Color)

    Order #: 17XX-CABLE-MARKER-SET

    Mfg #: 5312406

    Availability: Ships in 3-4 weeks
    Special Price $179.47 Regular Price $216.23
General Specifications Key features
1770 Series Three-Phase Power Quality Analyzers
Warranty Analyzer: 2 years (battery not included)
Accessories: 1 year (including battery)
Calibration cycle 2 years
Size (L X W X HD) 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in)
Weight 2.1 kg (4.6 lb)
Anti-theft protection Slot to support Kensington lock
Environmental specifications
Operating temperature range -10 °C to 50 °C
Storage temperature range -20 °C to 60 °C
Operating humidity IEC 60721-3-3: 3K5, modified:
-10 °C to 30 °C: ≤95 %, no condensation or ice
35 °C: 70 %
40 °C: 55 %
50 °C: 35 %
IP Rating IEC 60529: IP50
Vibration IEC 60721-3-3 / 3M2
Power supply
Voltage range 100 V - 600 V -15 % / +10 % (85 V ... 660 V)
Power consumption Max. 40 VA
Mains frequency 50/60 Hz (42.5 Hz ... 69 Hz)
UPS Li-Ion battery BP1770 with extended temperature range, customer replaceable
On-battery runtime: 1.5 hours
Safety
General IEC 61010-1: Pollution Degree 2
Power supply Overvoltage Category IV 600 V
With Mains Adapter MA-C8: Overvoltage Category II 300 V
Measurement IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V
Altitudes 2000 m to 4000 m Derate to:
Power Supply: Category IV 300 V
With MA-C8 Adapter: Category II 150 V
Measurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V