Fluke Thermal Imager Selection Guide
Thermal Imagers or Infrared Thermometers are valuable tools that can have a significant impact on your troubleshooting and maintenance productivity, as well as the bottom line, for industrial, electrical and building applications. It is important that you choose the right thermal imager for your application.
Some questions to consider:
Do I need High Temperature, High Accuracy or both?
Will I be measuring close up or at a distance that may require a special lens?
Do I need to store data taken in the field?
Will I need to generate reports?
Do I need video recording or just still pictures?
This Thermal Imager Selection Guide can help you choose the right tool for your application and budget. Click on the model number to get detailed specifications and pricing.
Compare Features
Models | Expert Series IR Cameras | Professional Series IR Cameras | Performance Series IR Cameras | |||||||||||||
TiX1000 | TiX660 | TiX640 | TiX560 | TiX520 | Ti400 | Ti300 | Ti200 | TiS65 | TiS60 | TiS55 | TiS50 | TiS45 | TiS40 | TiS20 | TiS10 | |
Detector resolution | 1024 x 768, 2048 x 1536, Super Res. | 640 x 480, 1280 x 960, Super Res. | 640 x 480 | 320 x 240, 640 x 480, Super Res. | 320 x 240, 640 x 480, Super Res. | 320 x 240 | 240 x 180 | 200 x 150 | 260 x 195 | 260 x 195 | 220 x 165 | 220 x 165 | 160 x 120 | 160 x 120 | 120 x 90 | 80 x 60 |
Spatial resolution | 0.6 mRad | 0.8 mRad | 0.8 mRad | 1.31 mRad | 1.31 mRad | 1.31 mRad | 1.75 mRad | 2.09 mRad | 2.4 mRad | 2.4 mRad | 2.8 mRad | 2.8 mRad | 3.9 mRad | 3.9 mRad | 5.2 mRad | 7.8 mRad |
Field of view | 32.4° x 24.7° | 30.9° x 23.1° | 30.9° x 23.1° | 24° x 17° | 24° x 17° | 24° x 17° | 24° x 17° | 24° x 17° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° | 35.7° x 26.8° |
Distance to Spot | 1811:1 | 1187:1 | 1187:1 | 764:1 | 764:1 | 764:1 | 573:1 | 477:1 | 417:1 | 417:1 | 353:1 | 353:1 | 257:1 | 257:1 | 193:1 | 128:1 |
Thermal sensitivity | 50 mK | 30 mK | 30 mK | 50 mK | 50 mK | 50 mK | 50 mK | 75 mK | 80 mK | 80 mk | 80 mk | 80 mk | 90 mK | 90 mK | 100 mK | 150 mK |
Temperature range | -40 °C to +1200 °C (-4 °F to +2192°F)1 | -40 °C to +1200 °C (-4 °F to +2192°F)1 | -40 °C to +1200 °C (-4 °F to +2192°F) | -20 °C to +1200 °C (-4 °F to +2192°F) | -20 °C to +850 °C (-4 °F to +1562°F) | -20 °C to +1200 °C (-4 °F to +2192°F) | -20 °C to +650 °C (-4 °F to +1202°F) | -20 °C to +650 °C (-4 °F to +1202°F) | -20 °C to +550 °C (–4 °F to 1022 °F) |
-20 °C to +550 °C (–4 °F to 1022 °F) |
-20 °C to + 450 °C (–4 °F to 842 °F) |
-20 °C to + 450 °C (–4 °F to 842 °F) |
-20 °C to +350 °C (–4 °F to 662 °F) |
-20 °C to +350 °C (–4 °F to 662 °F) |
-20 °C to +350 °C (–4 °F to 662 °F) |
-20 °C to +250 °C (–4 °F to 482 °F) |
Focus systems | LS, AF, MF, ES | LS, AF, MF, ES | AF, MF, ES | LS, AMF | LS, AMF | LS, AMF | LS, AMF | LS, AMF | MF | FF | MF | FF | MF | FF | FF | FF |
Laser distance meter | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | — | — | — | — | — | — | — | — |
Image enhancement | IRF, SR | IRF, SR | IRF | IRF, SR, IS | IRF, SR | IRF | IRF | IRF | IRF, PIP | IRF, PIP | IRF, PIP | IRF, PIP | IRF, PIP | IRF, PIP | IRF | — |
Annotation | VA, TA | VA, TA | VA, TA | IRPN, VA, TA | IRPN, VA, TA | IRPN, VA, TA | IRPN, VA | IRPN, VA | IRPN, VA | IRPN, VA | IRPN, VA | IRPN, VA | VA | VA | — | — |
Standard video rec. | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | — | — | — | — | — | — |
Radiometric video rec. | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | — | — | — | — | — | — |
Optional lenses | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | — | — | — | — | — | — | — | — |
Compare Specifications
Models | Expert Series Thermal Imager | Professional Series Thermal Imagers | Performance Series Thermal Imagers | |||||||||||||
TiX1000 | TiX660 | TiX640 | TiX560 | TiX520 | Ti400 | Ti300 | Ti200 | TiS65 | TiS60 | TiS55 | TiS50 | TiS45 | TiS40 | TiS20 | TiS10 | |
IFOV (spatial resolution) | 0.6 mRad | 0.8 mRad | 0.8 mRad | 1.31 mRad | 1.75 mRad | 2.09 mRad | 2.4 mRad | 2.8 mRad | 3.9 mRad | 5.2 mRad | 7.8mRad | |||||
Detector resolution | 1024 x 768 (786,432 pixels) Super Resolution mode: 2048 x 1536 (3,145,728 pixels) |
640 x 480 (307,200 pixels) Super Resolution mode: 1280 x 960 (1,228,800 pixels) |
640 x 480 (307,200 pixels) |
320 x 240 (76,800 pixels) Super Resolution mode: 640 x 480 (307,000 pixels) | 320 x 240 (76,800 pixels) |
240 x 180 (43,200 pixels) |
200 x 150 (30,000 pixels) |
260 x 195 (50,700 pixels) |
220 x 165 (36,300 pixels) |
160 x 120 (19,200 pixels) |
120 x 90 (10,800 pixels) |
80 x 60 (4,800 pixels) |
||||
Field of view | 32.4° H X 24.7° V | 30.9° H x 23.1° V | 24° H x 17° V | 35.7° H x 26.8° V | ||||||||||||
Optional lenses | Capture spectacular images close up or from a distance with optional lenses: 2 wide angle, 2 telephoto, 3 macro and 1 standard |
Optional telephoto and wide angle lenses available | — | |||||||||||||
Wireless connectivity | Fluke Connect™ app compatible with Fluke Connect® WiFi SD Card1 | Fluke Connect® app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN1 | ||||||||||||||
IR-Fusion® | AutoBlend™ mode, continuous blending | AutoBlend™ mode | 5 presets (0 %, 25 %, 50 %, 75 %, 100 %) | 3 presets (0 %, 50 %, 100 %) |
– | |||||||||||
Picture-In-Picture (PIP) | Picture-in-Picture | 5 presets (0 %, 25 % ,50 %, 75 %, 100 %) | – | |||||||||||||
Focus system | LaserSharp® Auto Focus, auto focus, manual focus, and EverSharp multifocal recording | Auto focus, manual focus, and EverSharp multifocal recording | LaserSharp® Auto Focus with built-in laser distance meter and advanced manual focus | Manual focus | Fixed focus | Manual focus | Fixed focus | Manual focus | Fixed focus | |||||||
Display | 5.6 inch color TFT display, 1280 × 800 pixel resolution, suitable for daylight operation | 5.7 inch touchscreen LCD, 640 x 480 pixel resolution | 3.5 inch touchscreen LCD, 640 x 480 pixel resolution | 3.5 inch (landscape) 320 x 240 LCD | ||||||||||||
Design | Camcorder with handle, Tiltable LCoS color viewfinder display, 800 × 600 pixel resolution |
Camcorder | Ergonomic FlexCam design with a 180 degree articulating lens | Rugged, ergonomic design for one-handed use | Rugged, lightweight, ergonomic design for one-handed use | |||||||||||
Thermal sensitivity | ≤ 0.05 °C at 30 °C target temp (50 mK) |
≤ 0.03 °C at 30 °C target temp (30 mK) | ≤ 0.045 °C at 30 °C target temp (45 mK); Filter Mode ≤ 0.03 °C at 30 °C target temp (30 mK) |
≤ 0.05 °C at 30 °C target temp (50 mK); Filter Mode ≤ 0.04 °C at 30 °C target temp (40 mK) |
≤ 0.05 °C at 30 °C target temp (50 mK) | ≤ 0.075 °C at 30 °C target temp (75 mK) |
≤ 0.08 °C at 30 °C target temp (80 mK) | ≤ 0.09 °C at 30 °C target temp (90 mK) | ≤ 0.10 °C at 30 °C target temp (100 mK) |
≤ 0.15 °C at 30 °C target temp (150 mK) |
||||||
Temperature measurement range | -40 °C to +1200 °C (-40 °F to 2192 °F) High temperature option—request at time of order: up to 2000 °C (3632 °F) |
-40 °C to +1200 °C (-40 °F to +2192 °F) |
-20 °C to +1200 °C (-4 °F to +2192 °F) |
-20 °C to +850 °C (-4 °F to +1562 °F) |
-20 °C to +1200 °C (-4 °F to +2192 °F) |
-20 °C to +650 °C (-4 °F to +1202 °F) | -20 °C to +550 °C (–4 °F to 1022 °F) | -20 °C to + 450 °C (–4 °F to 842 °F) | -20 °C to +350 °C (–4 °F to 662 °F) | -20 °C to +350 °C (–4 °F to 662 °F) |
-20 °C to +250 °C (–4 °F to 482 °F) |
|||||
Frame rate | 30 Hz or 9 Hz versions | 60 Hz or 9 Hz versions | 9 Hz or 30 Hz versions | 9 Hz | 9 Hz or 30 Hz versions | 9 Hz | 9 Hz or 30 Hz versions | 9 Hz | ||||||||
Sub-windowing modes available: (add-on at time of order-- sub-windowing options are not available on 9 Hz models) | Option 1: 640 × 480 (60 fps) Option 2: 384 × 288 (120 fps) Option 3: 1024 × 96 (240 fps) |
Option 1: 384 × 288 (120 fps) Option 2: 640 × 120 (240 fps) |
— | |||||||||||||
Software | SmartView® software and Fluke Connect® | |||||||||||||||
Voice annotation | Yes | – | ||||||||||||||
Text annotation | Yes | — | ||||||||||||||
Video recording | Standard and radiometric | — | ||||||||||||||
Streaming video (remote display) | Via HDMI; GigE Ethernet available in SmartView® software | Via USB or WiFi | — | |||||||||||||
Remote control | Yes | Yes | — | Yes | — | |||||||||||
Alarms | High temperature, low temperature, and Isotherms | High temperature, low temperature | – | |||||||||||||
Warranty | Two-years (standard), extended warranties are available |