Testo 350 for Rent, Portable Emission Analyzer
Order #: 350-RENT1
Mfg #: 350-RENT1
Product Highlights
Removable operating and display unit via Bluetooth or data bus cable
Increased measurement range for unlimited measurements even when gas concentrations are higher
Easy-to-change gas sensors and easy access to wearing parts
Sealed housing with built-in impact protection for use in harsh conditions
Easy operation of the analyzer unit via Control Unit or easyEmission software (both products available separately)
Emission analysis with up to 6 gas sensors - freely configurable
The testo 350 is a rugged, easy to use exhaust gas analyzer for carrying out precise industrial emission measurements and providing proper data administration. The Analysis Box can be operated with up to 6 gas sensors (5 optional). Select from sensors for CO, NO, NO2, SO2, H2S, CxHy and CO2
The rugged testo 350 exhaust gas analyzer is ideal for a wide range of professional industrial emission measurements and analysis applications, and is excellently suited for complex data compilation.
The testo 350 exhaust gas analyzer is made up of two separate units
The testo 350 Control Unit is used to control emission measurements. It has a clearly structured graphic display, and four different menu applications to choose from, including burner / gas turbine / motors / user-defined applications. The instructions on the display guide you through the measurement and make the steps leading up to it easier. This saves both time and hassle. The Control Unit can also be used to control the Analysis Box when it is not at the exhaust gas pipe or measurement site. This is advisable when working on larger systems.
The testo 350 Analysis Box contains the sensor system and electronics. It comes standard equipped with an O2 gas sensor. At least one more sensor (maximum of six) is needed to operate the Box. Optional sensors include sensors for CO, CO2, NO, NO2, SO2, H2S and CxHy
The increased measuring range (thinning) allows you to carry out unlimited measurements with higher gas concentrations. It is automatically activated when gas concentrations are unexpectedly high. The measuring range of a selected sensor can be increased by a certain factor. An opening on the underside gives you access to the relevant service and wearing parts, such as pumps and filters. The testo 350 also has numerous diagnosis functions with easy to understand readings and information. The analyzer constantly displays the current reading.
The Analysis Box can be controlled by the Control Unit or operated via USB, Bluetooth® 2.0, or CANCase from a PC or notebook. After the Analysis Box has been programmed, it can carry out measurements independently, save the results, and transfer the data to the Control Unit.
Conducting industrial emission measurements with the testo 350
The testo 350 exhaust gas analyzer has been specially designed for carrying out industrial emission measurements in the field. In the tab "Applications" you can find out more about:
- Emission measurements on industrial motors
- Emission measurements on burners
- Emission measurements on gas turbines
- Emission measurements on thermo processes
Delivery Scope
testo 350, O2 sensor, differential pressure sensor, type K NiCr-Ni and type S temperature sensor port, Pt10Rh-Pt, testo data bus port, rechargeable battery, built in combustion air sensor (NTC), trigger port, data memory, carrying strap set for the Control Unit and Analysis Box, USB interface and calibration certificate.
Looking for another Portable Emissions Analyzer? Check out the SEITRON S9000.
Temperature - NTC | |
---|---|
Measuring range | -4° to 122 °F / -20 to +50 °C |
Accuracy | ±0.4 °F (14° to 122 °F) / ±0.2 °C (-10 to +50 °C) |
Resolution | 0.1 °F (-4° to 122 °F) / 0.1 °C (-20 to +50 °C) |
Temperature - Type K TC | |
---|---|
Measuring range | -328.0° to 2498.0 °F / -200 to +1370 °C |
Accuracy |
|
Resolution | ±0.1 °F (-328.0° to 2498.0 °F) / 0.1 °C (-200 to +1370 °C) |
Temperature - TC Type S (Pt10Rh-Pt) | |
---|---|
Measuring range | 32.0° to 3200.0 °F / 0 to +1760 °C |
Accuracy | ±1.8 °F (32.0° to 3200.0 °F) / ±1 °C (0 to +1760 °C) |
Resolution | ±0.1 °F (32.0° to 3200.0 °F) / 0.1 °C (0 to +1760 °C) |
Differential Pressure | |
---|---|
Measuring range |
|
Accuracy |
|
Resolution |
|
Absolute Pressure | |
---|---|
Measuring range | 240 to +460 InH₂O / 600 to +1150 hPa |
Accuracy | ±4 InH₂O / ±10 hPa |
Resolution | 1 InH₂O / 1 hPa |
Flue gas O₂ | |
---|---|
Measuring range | 0 to +25 Vol.% |
Accuracy | ±0.8% of fsv (0 to +25 Vol.%) |
Resolution | 0.01 Vol.% (0 to +25 Vol.%) |
Reaction time t90 | 20 sec (t95) |
Flue gas CO | |
---|---|
Measuring range | 0 to +10000 ppm |
Accuracy |
|
Resolution | 1 ppm (0 to +10000 ppm) |
Reaction time t90 | 40 sec |
Flue gas COlow | |
---|---|
Measuring range | 0 to 500 ppm |
Accuracy |
|
Resolution | 0.1 ppm (0 to +500 ppm) |
Reaction time t90 | 40 sec |
Flue Gas NO | |
---|---|
Measuring range | 0 to +4000 ppm |
Accuracy |
|
Resolution | 1 ppm (0 to +4000 ppm) |
Reaction time t90 | 30 sec |
Flue gas NOlow | |
---|---|
Measuring range | 0 to +300 ppm |
Accuracy |
|
Resolution | ±0.1 ppm (0 to +300 ppm) |
Reaction time t90 | 30 sec |
Flue Gas NO₂ | |
---|---|
Measuring range | 0 to +500 ppm |
Accuracy |
|
Resolution | 0.1 ppm (0 to +500 ppm) |
Reaction time t90 | 40 sec |
Flue Gas SO₂ | |
---|---|
Measuring range | 0 to +5000 ppm |
Accuracy |
|
Resolution | 1 ppm (0 to +5000 ppm) |
Reaction time t90 | 30 sec |
Efficiency (calculated) | |
---|---|
Measuring range | 0 to +120 % |
Resolution | 0.1 % (0 to +120 %) |
Flue Gas loss (calculated) | |
---|---|
Measuring range | 0 to +99.9 % |
Resolution | 0.1 % (0 to +99.9 %) |
Flue Gas dewpoint (calculated) | |
---|---|
Measuring range | 0 to +99.9 °Ctd |
Resolution | 0.1 °Ctd (0 to +99.9 °Ctd) |
Flue Gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range | 0 to CO₂ max |
Accuracy | calculated from O₂ ±0.2 Vol.% |
Resolution | 0.01 Vol.% |
Flue gas H₂S | |
---|---|
Measuring range | 0 to +300 ppm |
Accuracy |
|
Resolution | 0.1 ppm (0 to +300 ppm) |
Reaction time t90 | 35 sec |
Flue Gas CO₂ - NDIR | |
---|---|
Measuring range | 0 to +50 Vol.% |
Accuracy |
|
Resolution |
|
Reaction time t90 | 10 sec |
Velocity / Volume flow | |
---|---|
Measuring range | 0 to +7874 fpm / 0 to +40 m/s |
Resolution | 19.7 fpm (0 to +7874 fpm) / 0.1 m/s (0 to +40 m/s) |
Methane (CH?) | |
---|---|
Measuring range | 100 to 40000 ppm |
Accuracy |
|
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (2 x mv methane) |
Reaction time t90 | < 40 sec |
Response factor | 1 |
Propane (C3H8) | |
---|---|
Measuring range | 100 to 21000 ppm |
Accuracy |
|
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (5 x mv propane) |
Reaction time t90 | < 40 sec |
Response factor | 1.5 |
Butane (C4H10) | |
---|---|
Measuring range | 100 to 18000 ppm |
Accuracy |
|
Resolution | 10 ppm |
Min. O₂ requirement in flue gas | 2 % + (6.5 x mv butane) |
Reaction time t90 | < 40 sec |
Response factor | 2 |
General technical data | |
---|---|
Weight | 169 oz. / 4800 g |
Dimensions | 13 x 5 x 17 in. / 330 x 128 x 438 mm |
Operating temperature | 23.0° to 113.0 °F / -5 to +45 °C |
Housing | ABS |
Protection class | IP40 |
Connectable probes | 1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
Product colour | Black |
Battery type | lithium batteries |
Battery life | 5 h |
Power supply | AC mains unit 100V to 240V (50 to 60 Hz) |
DC electric tension input | 11V to 40V |
Pump flow | 1 l/min. with through-flow monitoring |
Hose length | 16.2 m (corresponds to 5 probe hose extensions) |
Max. pos. press./flue gas | 0.725 psi / 50 mbar |
Max. neg. press./flue gas | -4.351 psi / -300 mbar |
Max. dust load | 20 g/m3 dust in flue gas |
Dewpoint calculation | 0 °Ctd; 99 °Ctd |
Max. humidity load | 70 °C dewpoint temperature |
Trigger input | Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA |
Maximum | 250,000 readings |
Interface | data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension |
Storage temperature | -4.0° to 122.0 °F / -20 to +50 °C |