Tektronix THDPO100 for Rent, Differential High Voltage Probe, 100 MHz
Differential High Voltage Probe 100 MHz

Order #: THDPO100-RENT2

Mfg #: THDPO100

Questions about availability or need help? Contact Us:

(800) 633-0561
Call for price
Call for price

Tektronix THDPO100 for Rent, Differential High Voltage Probe, 100 MHz

Differential High Voltage Probe 100 MHz

Order #: THDPO100-RENT2

Mfg #: THDPO100

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price

A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at the ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common-mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.

Features

  • Attenuation: 100X / 1000X
  • Bandwidth: 100 MHz
  • Input Impedance: 40 MΩ || 2.5 pF
  • Maximum Voltage
    • 1000X: ± 6000 V
    • 100X: ± 600 V
  • Selectable Bandwidth-limiting Filters
  • DC Reject
  • Small Compact Probe Head for Probing Small Geometry Circuit Elements
  • Straight Pin, Square Pin, Solder Down, Variable Pitch Standard Accessories
  • Robust Design for Reliability
  • Provides Automatic Units Scaling and Readout on the Oscilloscope
Bandwidth (Probe only) 100 MHz
Attenuation 100X / 1000X
Rise Time (Probe only) <700 ps
Differential Input Capacitance 2.5 pF
Differential Input Resistance 40 MΩ
CMRR >55 dB at 30 kHz
>50 dB at 1 MHz
>18 dB at 250 MHz (warranted at 50x attenuation)
Sensitivity/Noise Level 2 mV RMS (5x attenuation)
1 mV RMS (50x attenuation) referred to the probe output
10 mV RMS (5x attenuation)
50 mV RMS (50x attenuation) referred to the probe input
Differential Mode Input Voltage ±42 V (DC + pk AC); 30 V RMS
Common Mode Input Voltage ±35 V (DC + pk AC); 25 V RMS
Input Offset Range ±42 V (5x or 50x attenuation)
Max Input Voltage (Nondestruct) ±100 V (DC + pk AC)
Selectable Bandwidth Filter Limits 100 Hz, 10 kHz, 1 MHz, Full
DC Reject 0.4 Hz (5x)
4 Hz (50x)
Gain Accuracy at DC ±2%
Propagation Delay 6.5 ns
Scope Interface TekVPI™ Probe Interface