NH Research 9410-36 for Rent, AC/DC Power Supply - 1 to 3 Phase 400V/Phase 90A/Phase, 36kW
AC/DC Power Supply,1-to 3-Phase 400V/Phase,90A/Phase,36kW
Order #: 9410-36-RENT2
Mfg #: 9410-36-RENT2
Call for price
Call for price
NH Research 9410-36 for Rent, AC/DC Power Supply - 1 to 3 Phase 400V/Phase 90A/Phase, 36kW
AC/DC Power Supply,1-to 3-Phase 400V/Phase,90A/Phase,36kW
Order #: 9410-36-RENT2
Mfg #: 9410-36-RENT2
Call for price
Call for price
Product Highlights
The 9410 from NH Research is a four-quadrant (bi-directional) AC/DC source with selectable phase outputs, a built-in waveform-digitizing measurement system and robust line disturbance creation tools. When used in the regenerative (sink) mode, it sends returned power back to the facility mains rather than being dissipated as heat. The most frequent application of the 9410 is use as a grid simulator for testing PV inverters and other grid-tied products for compliance to industry standards.
Features
- 8 models 4kW/10.5kVA to 96kW/252kVA
- Output AC Voltage Ranges 175, 350VRMS L-N
- Output DC Voltage 200, 400VDC
- Output Frequency DC, 30 to 100Hz
- Programmable 1, 2 or 3-Phase modes
- Full 4 quadrant AC source operation
- High resolution waveform capture on all V & I
- Sink power regenerated back to facility
- 9" Touch-Panel user interface
- SCPI programming & NI LabVIEW drivers
Advantages
- Bi-directional AC Inverter testing & µgrid simulation
- More reactive power per kW
- Simplifies automated test stand development
- Software selectable 1, 2, or 3 Phase operation
- Isolated digital inputs & outputs
- Built-in SW watchdog & safety limits
- Software tools to shorten test development time
- PC-based tools & NI certified drivers
- NI certified LabVIEW & IVI-C/IVI-COM drivers
- Optional: Enerchron® test sequencer
Benefits
- Regenerative, returns greater than 85% of power to the facility, which provides significant electrical savings.
- Field upgradeable to higher power
- Fully emulate any utility/grid condition
- Simulate non-ideal Phase phase angles (A-B & A-C)
Model Number | 9410-36 |
AC Output Ratings | |
Phases/Output Channels | 1,2, or 3|
Power, Max (1Φ or 3Φ) | 36kW/94.5kVA |
Current Ranges (RMS per Φ) | 18, 90 A/Φ |
Current Ranges (RMS 1Φ) | 54, 270A |
Peak Current | 3 X Max RMS |
Frequency | 30-100Hz (option up to 880Hz) |
Voltage Ranges, L-N | 175, 350V (Split Phase 250V Max) |
Accuracy | 0.2% Set + 0.2% Rng |
Resolution | 0.005% Rng |
Distortion (THD) | <1% @ 50/60Hz (Full power into resistive load at 480 VRMS (L-L)) |
Response Rate | 1V/µS (10% to 90% measured at 90 degree turn-on into resistive load) |
Custom Waveforms | Sine, n-Step Sine, Triangle, Clipped-Sine, Arbitrary (user defined) |
Phase Angle Control | 0 to 359 degrees/1 degree resolution |
DC Output Ratings | |
Power Max (1ch or 3ch) | 36kW |
Current Ranges (Per Ch.) | 18, 90A/CH |
Current Ranges (Per System) | 54, 270A |
Voltage Ranges | 200, 400 VDC |
Accuracy | 0.2% Set + 0.2% Range |
Ripple | <800mV RMS |
AC & DC Measurements | |
Peak Voltage | 250, 500V |
Accuracy (AC RMS) | 0.1% Rdg + 0.06% Rng |
Accuracy (DC) | 0.1% Rdg + 0.1% Rng |
Accuracy (Peak) | 0.5% Rdg + 0.2% Rng |
Resolution | 0.005% Rng |
Peak Current (per Ch.) | 60, 300A |
Accuracy (AC RMS) | 0.2% Rdg + 0.06% Rng |
Accuracy (DC) | 0.2% Rdg + 0.06% Rng |
Accuracy (Peak) | 0.5% Rdg + 0.2% Rng |
Resolution | 0.005% Rng |
Peak Power | V Range x I Range |
Accuracy (AC RMS) | 0.2% Rdg + 0.06% Rng |
Resolution | 0.005% Rng |
Additional Measurements | Energy (Ah, kWh, kVAh), AC Crest Factor, AC Power Factor, Waveform Capture |
Physical | |
Enclosure | Cabinet |
Size (HxWxD) | 61 x 23 x 30"/1549 x 584 x 762mm |
Weight | 505lbs/229kg |