Order #: 568-EX-RENT1
Mfg #: 568-EX-RENT1
Fluke 568-EX/ETL for Rent, Intrinsically Safe Mini Infrared Thermometer
Order #: 568-EX-RENT1
Mfg #: 568-EX-RENT1
Product Highlights
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.
With a straight-forward user interface and soft-key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.
- Intrinsically safe temperature measurements. Anywhere in the world
- Measure -40 °C to 800 °C
- (-40 °F to 1472 °F) with ± 1 %
- Measurement Accuracy
- Conductive Case for Carrying into
- Hazardous Areas
- 50:1 Distance-to-Spot Ratio
- Compatible with Standard K-Type
- Mini-Connector Thermocouple
- (KTC) Probe
- Adjustable Emissivity, Built-in
- Material Table
- Capture up to 99 Points of Data
- Two-Year Warranty
Specifications | |
Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) |
Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); |
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater | |
Display resolution | 0.1°C / 0.1°F |
Infrared spectral response | 8 µm to 14 µm |
Infrared response time | < 500 ms |
Thermocouple type-k input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
Thermocouple type-k input accuracy | < -40°C: ±(1°C + 0.2°/1°C) |
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F) | |
≥ -40°F: ±1% or 2°F, whichever is greater | |
D:S (distance to measurement spot size) | 50:01:00 |
Laser sighting | Single-point laser |
Minimum spot size | 19 mm (0.75 in) |
Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
Data storage | 99 points |
Hi/Low alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Display | Dot matrix with function menus |
Backlight | Two levels, normal and extra bright for darker environments |
Trigger lock | Yes |
Switchable celsius and fahrenheit | Yes |
Power | 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.) |
Battery life | 4 hours with laser and backlight on; |
100 hours with laser and backlight off, at 100% duty cycle | |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Storage temperature | -20°C to 60°C (-40°F to 140°F) |
Bead thermocouple type-k range | -40°C to 260°C (-40°F to 500°F) |
Bead thermocouple type-k accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), |
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |