Fluke Calibration 9100S-A Handheld Dry-Well, Insert A, 6 wells, 35C to 375C (95F to 707F), NIST
Handheld Dry-Well A 35C to 375C (95F to 707F), NIST

Order #: 5853T

Mfg #: 2431771

Questions about availability or need help? Contact Us:

(800) 633-0561

Fluke Calibration 9100S-A Handheld Dry-Well, Insert A, 6 wells, 35C to 375C (95F to 707F), NIST

Handheld Dry-Well A 35C to 375C (95F to 707F), NIST

Order #: 5853T

Mfg #: 2431771

Availability: Ships in 2-3 weeks

Choose Your Options:

This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

Since Fluke introduced the world's first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.

It's simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375C (707F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.

Plug it in, switch it on (Note, these wells are fixed and not interchangeable,) set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of +/-0.5C, a stability of +/-0.1C, and a stabilization time of just five minutes.

  • Fixed Block Options: Size of these standard block options are: 1/4", 1/8", (2) 3/16" , 1/16", 5/32"
  • Range: 35°C to 375°C (95° to 707°F)
  • Accuracy: 35° to 200°C ±0.5°C
  • 200 to 300°C ±1°C
  • Stability: ±0.2°C at 50°C
  • ±0.3°C at 300°C
  • Well-to-Well Uniformity: ±0.2°C with sensors of similar size at equal depths within wells
  • Heating Times: 35°C to 300°C; 9.5 minutes
  • Stabilization: 5 Minutes
  • Cooling Times: 300°C to 100°C; 14 Minutes
  • Well Depth: 4 Inches (102 mm)
  • 1/16" (1.6mm) hole is 3.5" (89 mm) deep
  • Size: 2.25"H x 4.9"W x 5.9"D (57 x 125 x 150 mm)
  • Weight: 2lb. 3oz. (1 kg)
  • NIST Certificate data points taken at 50°, 100°C, 150°C, 200°

Each Unit Includes

  • Manufacturer's NIST-Traceable Certificate
  • Instructions

Webinars

Automating and Documenting Temperature Calibration Webinar with Fluke Calibration