1.5 m (60 in) Shielded Coaxial cable with BNC plug
Maximum Conductor Size
52.0 mm (2.05 in)
Maximum Jaw Opening
81.5 mm
Output to Zero
Auto adjustment with Zero button
Temperature Operating
-10 °C to 50 °C (14 °F to 122 °F)
Storage (battery removed)
-30 °C to +60 °C (-22 °F to +140 °F)
Operating Humidity
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
Altitude Operating
2,000 m (6560 ft)
Storage
12,000 m (40,000 ft)
Demagnetize Clamp
Open and close the Clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less.
Safety
IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
Ingress Protection
IEC 60529, IP40
Power Supply Type
2 x AA alkaline battery, IEC LR6
Battery Life
150 hours (typically)
Low battery indicator
Yes
Electrical Specifications
Current Range
2000 A ac rms, ± 2000 A dc
Output Sensitivity
1 mV/A
Accuracy
± 0.8 % of reading ± 0.2 % of range
Bandwidth for Accuracy Specification
DC to 400 Hz
Load impedance
>1 MΩ and
Frequency Response (small signal)
DC to 20 kHz (-3 dB)
Temperature Coefficient
0.1 x specified accuracy for each degree C above 28 °C or below 18 °C