The store will not work correctly when cookies are disabled.
JavaScript seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Javascript in your browser.
Your company account is blocked and you cannot place orders. If you have questions, please contact your company administrator.
Fluke 116/323 KIT HVAC Combo Kit - Includes Multimeter and Clamp Meter
HVAC Combo Kit - Includes Multimeter and Clamp Meter
Order #: 116/323 KIT
Mfg #: 4296029
Special Price
$520.46
Regular Price
$584.79
Special Price
$520.46
Regular Price
$584.79
This product is available for shipping to the United States, Canada, and Puerto Rico only.
Overview
Everything You Need in an HVAC Meter
With the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V Environments.
Product Highlights For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case Each Unit Includes Fluke 116 HVAC Multimeter with Temperature and Microamps Fluke 323 True-rms Clamp Meter
Special Price
$69.76
Regular Price
$78.39
Special Price
$305.26
Regular Price
$342.99
Special Price
$133.13
Regular Price
$149.59
Special Price
$427.36
Regular Price
$480.19
Special Price
$69.76
Regular Price
$78.39
Special Price
$262.43
Regular Price
$312.79
Special Price
$290.48
Regular Price
$326.39
Special Price
$228.19
Regular Price
$271.99
Special Price
$62.74
Regular Price
$74.79
Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
±([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy
±([% of reading] + [counts]): 0.5% + 2
Auto volts
Range/resolution
600.0 V / 0.1 V
Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy
0.9% + 1
Range/Resolution
40.00 MΩ / 0.01 MΩ
Accuracy
5% + 2
Diode Test
Range/resolution
2.00 V / 0.001 V
Accuracy
0.9% + 2
Capacitance
Range/resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy
1.9% + 2
Range/resolution
> 1000 μF
Accuracy
5% + 20%
Lo-Z Capacitance
Range
1 nF to 500 μF
Accuracy
10% + 2 typical
Temperature²
Range/resolution
-40°C to 400°C / 0.1°C
(Type-K thermocouple)
Accuracy
1% + 10²
Range/resolution
-40°F to 752°F / 0.2°F
Accuracy
1% + 18²
AC μA true-rms (45 Hz to 500 Hz)
Range/resolution
600.0 μA / 0.1 μA
Accuracy
1.5% + 3
DC μamps
Range/resolution
600.0 μA / 0.1 μA
Accuracy
1.0% + 2
Hz (V or A input)²
Range/resolution
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy
0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight
550 g
Warranty
3 years