The Fluke Networks CFP-100-QI-W is the CertiFiber Pro Quad OLTS with a double ended inspection kit and 1 year Gold Support. The Fluke Networks Versiv family of cable testers offer modular solutions for every copper and fiber cable testing application. Check out our OptiFiber Pro product page to view all of your ordering options.
Availability:Ships in 3-4 weeks
This product is available for shipping to the United States only.
Taptive user interface provides simple, animated guidance to eliminate incorrect reference setup and negative losserrors.
Convenient quad module supports both multimode and singlemode loss testing
Extended singlemode distance range to 130km
Built in Visual Fault Locator
Analyze test results and create professional test reports using LinkWare Management Software
Compatible with Linkware Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare PC Cable Test Management Software.
Each Unit Includes
(2) Versiv Mainframes
(2) CertiFiber Pro Quad OLTS Modules
(2) USB fiber inspection video probes each with 4 tips
Multimode Encircled Flux compliant test reference cord kit (2m) for testing 50um LC terminated fibers (2 SC/LC, 2 LC/LC)
Singlemode test reference cord kit (2m) for testing 9um LC terminated fibers (2 SC/LC, 2 LC/LC)
TRC Carrying Case
(2) 1.25 mm Quick Clean Cleaners
(2) 2.5 mm Quick Clean Cleaners
(2) LC/LC Adaptors
(2) Hand Straps
(2) Shoulder Straps
Carry Case
USB Interface Cable
Versiv Open Source Software CD
(2) AC Chargers
WiFi adapter
Statement of Calibration and Getting Started Guide
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type
InGaAs
Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 _W (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 _m and NA = 0.14 for 9/125 _m. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.
Loss/Length Specifications
Specification
CertiFiber Pro Multimode Modules
CertiFiber Pro Singlemode Modules
Testing Speeds (excludes referencing times)
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
1. At the output of the EF-TRC 2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor 3. Relative to power level after 15 minute warm up – at constant temperature
Loss/Length Specifications (continued)
Source Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0.1 dB
Re-calibration Period
1 year
1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 _W (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 _m and NA = 0.14 for 9/125 _m. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5-minute warm-up.