Order #: ADT227
Mfg #: ADT227
Additel ADT227 Documenting Process Calibrator, Temperature and Pressure
Order #: ADT227
Mfg #: ADT227
Product Highlights
Documenting Process Calibrator, ADT227, Temperature and Pressure
- Sourcing, simulating and measuring pressure, temperature and electrical signals
- Built-in Full Hart Communicator (ADT227-HART)
- Built-in Barometer
- Intrinsically safe models available (Ex)
- Large Smartphone Like Touchscreen User Experience
- USB Type-C and Bluetooth communications
- IP67 Rated
- High Voltage Mesurement Capability (±300V AC)
- True RMS Voltage Meter Capability
- Dual channel pressure module ports
- High Static Differential Pressure Measurement 0.002% FS
- ISO 17025-accredited calibration w/data included
Additel's new Multi-functional Documenting Process Calibrator series takes portability, functionality, and accuracy to a whole new level and packages it with an intuitive and easy to use color touchscreen display. This series includes an advanced documenting pressure calibrator (ADT227) and an advanced documentation process calibrator with a builtin HART communicator (ADT227-HART). Additionally, each calibrator has an ATEX certified intrinsically safe option (ADT227Ex) allowing you to perform calibration in the harshest of environments. We're confident these new tools will not only meet your calibration requirements but will make metrology simple for you!
Easy-to-use Cellphone Like Interface
The ADT227 series brings an all new user interface to the world of process calibrators. With a menu driven interface and a small size/weight, the ADT227 is the industry's smallest advanced multifunctional process calibrator with an intrinsically safe version to boot (ADT227Ex). It adopts advanced human hand engineering design for the most convenient field handheld process calibrator available. The ADT227 has been developed with a powerful embedded operating system which solves common problems of other designs including slow response, cumbersome key operation, high power consumption and overall slow processing.
Accuracy
Additel's new and improved ADT227 series provides much improved accuracies including an electrical accuracy of 0.005% RD + 0.005% FS, high-static differential pressure mode accuracy to 0.002% FS and across the board improvements in temperature measurement accuracies.
Thermocouple Measurement Performance
The ADT227 series delivers highly improved thermocouple measurement capabilities by vastly improving the cold junction compensation (CJC) specifications and a much-improved stabilization time.
Portable and Robust
The demands of remote calibration work can be challenging. The ADT227series is lightweight and highly portable and utilizes an advanced color LCD screen to help ensure you can easily see, even in the (Ex) intrinsically safe versions. All models in the ADT227 family have been designed with ruggedness and dependability in mind and meet IP67 standards with a 1-meter drop test, 4G vibration, xenon exposure and 130g steel ball drop testing of the display. Other environmental conditions have also been considered, such as temperature and humidity. To combat these external elements, Additel has designed a unique internal circuit design and process technology to allow for the utmost confidence in your critical calibration and measurement work.
Intrinsically Safe Option
The Additel 227Ex series calibrators have passed the most stringent testing by certified organizations to acquire intrinsically safe certificates, ATEX, IECEX, CSA and UKCA. The explosion-proof grade (Ex ia IIC T4 Ga), can be widely used in potentially explosive environments, such as oil and gas platforms, oil refineries, chemical and petrochemical plants, pharmaceutical industries, energy and gas processing industries. Each intrinsically safe calibrator has an advance transflective color LCD display which has enhanced visibility when viewed in direct sunlight. No matter where your work takes you, these calibrators are up to the task.
Voltage Meter (RMS)
The Additel 227 non-Ex version is equipped with "true effective value" RMS measuring function, which can measure the RMS of various waveforms with no need to consider distortion or waveform parameters and different errors caused by different waveforms.
Automated Tasks for Paperless Calibration Management
Additel 227 Series Calibrators come with a power documenting calibration task application which provides a turnkey solution for automation and paperless calibration management. Tasks are easily created for temperature, pressure, flow and loop instruments. Up to 10,000 documented tasks can be stored in the extensive on-board memory. Many tasks, when executed, are fully automated in data collection and performance validation, such as pass/fail and hysteresis calculations. All information can be integrated into Additel's ACal software for additional calibration management.
Full HART Communicator
The built-in full HART communicator will work with most HART transmitters. The ADT227-HART contains an extensive DD library to meet the needs of your smart transmitter. Our DD library is updated on a regular basis and at no additional cost. The ADT227Ex-HART is integrated with the HART communication functions permitting users to monitor, control, and calibrate HART instrumentations. It's an ideal device for calibrating, maintaining, and troubleshooting HART instrumentations.
Targeted application features
The onboard applications provide a useful selection of features including HART communicator, high static differential pressure mode, pressure leak test, safety valve test, analog transmitter calibration, unit converter, thermal calculator, and snapshots to name a few. High static differential pressure mode uses two sensors, unique calculation technology to achieve a differential pressure measurement to 0.002% FS at high static pressures. The leak test will automatically calculate the pressure drop to determine a leak condition. The safety valve test is a specialized task which captures the exact pressure release point by taking 10 readings per second during a valve crack test. You will find this and much more as we continue to develop new apps at Additel.
Data Logger
Record pressure, temperature and electrical signals readings over a long period. Recorded values can be displayed numerically or graphically to identify trending. On-board memory can store up to 10,000 readings or 1,000 readings and is easily exported to Additel application software. Each log session is easily configured at a set interval and each reading is provided with a date and time stamp.
Connectivity & Battery
Users can remotely connect mobile devices to the ADT227 via Bluetooth and Wi-Fi communication with an unobstructed distance up 20 meters. The included USB type-C comm port and cable provide a hard-wired communication option as well as charging for the removeable Li-ion battery, which provides up to 35 hours of run time.
Time Saving Features
In addition to all the great features mentioned above, the ADT227series is loaded with time saving features like our built in pressure and temperature converter, thermal calculator, wiring diagram guide for assisting with electrical connections, a built-in diagnostic center including intelligent alarm messaging and a real time error report and comprehensive self-testing to help our customers get the very most out of their investment in Additel calibration tools.
Each Unit Includes
- 9811-X 110V/220V external power adapter(Only for ADT227, 227P)
- 9704 Chargeable Li-ion battery(Only for ADT227, 227P)
- 9023 Test leads, 1 set
- 9027 Right angle test leads(Non-Ex models only) 1 set
- 9060 Pressure module connection cable
- 9052 USB Cable type A to type C (Non-Ex models only)
- 9040 Hanging strap with magnet
- 9028 Multimeter Test Hook, Flexible Electronic Probe1 set
- ISO 17025 accredited calibration certificate
- Additel ADT161 Intelligent Digital Pressure Module
Intelligent Digital Pressure Module
Order #: ADT161
Mfg #: ADT161
Availability: Call for availability$1,946.00 - Additel 9060 Press Module Connection CablePress Module Connection Cable
Order #: 9060ADT
Mfg #: 9060
Availability:In stock$155.40 - Additel 9080 Cold Junction Kit (TC Plug, Cable, S, R, B, K, J, T, E, N)Cold Junction Kit (incl TC Plug, Cable, S,R,B,K,J,T,E,N)
Order #: 9080ADT
Mfg #: 9080
Availability: Ships in 2-3 weeks$694.40 - Additel 9704 Battery, rechargeable Li-ion polymer battery for HandheldsBattery, rechargeable Li-ion polymer battery for Handhelds
Order #: 9704-ADDITEL
Mfg #: 9704
Availability: Ships in 2-3 weeks$292.60 - Additel 9811-US Power Adapter, external power adapter (US plug)Power Adapter, external power adapter (US plug)
Order #: 9811-US
Mfg #: 9811-US
Availability: Ships in 2-3 weeks$128.80 - Additel 9906A Carrying case for handheld calibratorsCarrying case for handheld calibrators
Order #: 9906A
Mfg #: 9906A
Availability: Ships in 2-3 weeks$564.20 - Additel 9918-SC Soft Carrying CaseSoft Carrying Case
Order #: 9918-SC
Mfg #: 9918-SC
Availability:In stock$319.20 - Additel 9530-NET Automatic Calibration Software with Asset ManagementAdditel/Acal Auto.Calibration Software w/Asset Management
Order #: 9530-ADDITEL
Mfg #: 9530-NET
Availability: Ships in 2-3 weeks$6,477.80 - Additel 9062 Pressure module cable, Black, 0.4m length, malePressure module cable, Black 0.4m length, male
Order #: 9062
Mfg #: 9062
Availability: Ships in 2-3 weeks$287.00
Electrical Specifications - Source Accuracy | ||||||
---|---|---|---|---|---|---|
Specifications | ADT227 | ADT227Ex | ||||
Range | Resolution | Accuracy | Range | Resolution | Accuracy | |
Voltage DC | 0 to 15V | 0.1 m | 0.005%RDG+0.005%FS | 0 to 10.5V | 0.1 m | 0.01%RDG+0.005%FS |
Current DC | 0 to 25 m | 0.1 A | 0.01%RDG+0.005%FS | 0 to 25 m | 0.1 A | 0.01%RDG+0.005%FS |
Resistance | 0 to 400 | 1 m | 0.005%RDG+0.005%FS | 0 to 400 | 1 m | 0.01%RDG+0.005%FS |
0 to 4000 | 10 m | 0.01%RDG+0.005%FS | 0 to 4000 | 10 m | 0.01%RDG+0.005%FS | |
Frequency | 0.01 to 50000.0 Hz | Auto range, 6-digit | 0.002%RDG+2 on last digit | 0.01 to 50000.0 Hz | Auto range, 6-digit | 0.002%RDG+2 on last digit |
Voltage m (TC) | -10 to 75 m | 0.1 V | 0.0008%RDG + 0.004%FS | -10 to 75 m | 0.1 V | 0.01%RDG + 0.004%FS |
Pulse | 0 to 9999999 | 1 | N/A | 0 to 9999999 | 1 | N/A |
Optional rising edge and falling edge, minimum threshold voltage: 2.V | ||||||
Loop power (mx 25m) | 24V | N/A | ±1V | 20V | N/A | ± 10% |
Electrical Specifications - measurement Accuracy | ||||||
---|---|---|---|---|---|---|
Specifications | ADT227 | ADT227Ex | ||||
Range | Resolution | Accuracy | Range | Resolution | Accuracy | |
Voltage DC | -300 to 300 m | 1 V | 0.005% RDG + 0.005% FS | -300 to 300 m | 1V | 0.01% RDG + 0.005% FS |
-30 to 30V | 0.1 m | 0.005% RDG + 0.005% FS | -30 to 30V | 0.1 m | 0.01% RDG + 0.005% FS | |
Temperature Coefficient: ±5 ppmFS/°C (-10°C to 10°C and 30°C to 50°C) | ||||||
Impedance: -300 m to 300 m => 100 m, -30 m to 30 m => 1 m | ||||||
DC High Voltage | -3 to 3V | 0.1 m | 0.05% RDG + 0.01% FS | N/A | ||
-30 to 30V | 1 m | 0.05% RDG + 0.01% FS | ||||
-300 to 300V | 10 m | 0.05% RDG + 0.01% FS | ||||
Temperature coefficient: ±0.0025% FS/°C (-10°C to 10°C and 30°C to 50°C) | ||||||
maximum Input Voltage = 300V, IEC61010 30V CATII | ||||||
Common mode rejection: >100 dB (at 50 or 60 Hz) | ||||||
Impedance: > 4 m, DC coupling | ||||||
AC High Voltage | V (40 to 500 Hz) | 0.1 m | 0.5% RDG + 0.05% FS | N/A | ||
3V (40 to 500 Hz) | 1 m | 0.5% RDG + 0.05% FS | ||||
30V (40 to 500 Hz) | 10 m | 0.5% RDG + 0.05% FS | ||||
Temperature coefficient: ±0.025% RD + 0.0025% FS?/°C (-10°C to 10°C and 30°C to 50°C) | ||||||
maximum Input Voltage = 300V, IEC61010 30V CATII | ||||||
9% to 100% of range is suitable for the above accuracy indicators | ||||||
Impedance: >4 m, <100pF, AC coupling | ||||||
Current DC | -30 to 30 m | 0.1 A | 0.01% RDG + 0.005% FS | -30 to 30 m | 0.1 A | 0.01% RDG + 0.005% FS |
Temperature Coefficient: ±5ppmFS/°C (-10°C to 10°C and 30°C to 50°C), Impedance: < 40 | ||||||
Resistance (4-Wire) | 0 to 400 | 1 m | 0.005% RDG + 0.005% FS | 0 to 400 | 1 m | 0.01% RDG + 0.005% FS |
0 to 4000 | 10 m | 0.01% RDG + 0.005% FS | 0 to 4000 | 10 m | 0.01% RDG + 0.005% FS | |
Temperature coefficient: ±5 ppmFS/°C (-10°C to 10°C and 30°C to 50°C) | ||||||
2-Wire + 50 m, 3-wire+ 10 m | ||||||
Excitation current: 0.25 m | ||||||
Voltage m (TC) | -10 to 75 m | 0.1 V | 0.008% RDG + 0.004% FS | -10 to 75 m | 0.1 V | 0.01% RDG + 0.004% FS |
Temperature Coefficient: ±5ppmFS/°C (-10°C to 10°C and 30°C to 50°C) | ||||||
Impedance: >100 m | ||||||
Frequency | 0.01 to 50000 Hz | Auto range, 6-digit | 0.002% RDG + 2 on last digit | 0.01 to 50000 Hz | Auto range, 6-digit | 0.002% RDG + 2 on last digit |
minimum threshold voltage: 2.5V | ||||||
Supported units: Hz, kHz, mz, CPm CPH, s, m, µs | ||||||
Pulse | 0 to 9999999 | 1 | N/A | 0 to 9999999 | 1 | N/A |
Optional rising edge and falling edge, minimum threshold voltage: 2.V | ||||||
Switch | Supports dry or wet switches. Voltage range of 3 to 30V. Response speed < 10 m |
General Specification | ||
---|---|---|
ADT227 | ADT227Ex | |
Operating Temperature | -10°C to 50°C | |
Specification guaranteed Temperature range | 10°C to 30°C | |
Storage Temperature | -20°C to 60°C | |
Humidity | <90%, non-condensing | |
Power supply | 6600mh, 23.8Wh lithium battery, charging time 4~6 hours, battery pack can be charged independently | 4000mh 14.4Wh Explosion-proof lithium battery pack charging time 6~8 hours, battery pack can be charged independently |
User interface | Icon drive menus | Icon drive menus with navigation buttons |
Ports protection Voltage | 5V mx | 3V mx |
Display | 5.0 inch 480 x 800 m TFT LCD capacitive screen | 4.4 inch 640 x 480 m color display capacitive screen |
maximum altitude | 3000 meters | |
European Compliance | CE mark | |
Electrical Connection | Ø4m sockets and flat mini-jack thermocouple socket | |
Size | 6.97" x 4.13" x 2.04" (177 m x 105 m x 52 m) | |
Weight | 1.6 lb (0.7 kg) | 1.65 lb (0.75 kg) |
Battery | Rechargeable Li-ion battery (included) | |
Battery Life | Typically 16 hours | Typically 35 hours |
Battery Charge | 11V/22V external power adapter included. Battery can be charged external to the unit. Typically charge time is 6-8 hours. | |
External pressure module | Dual channel serial plug, can connect two digital pressure modules | |
Warmup time | Full specification performance is achieved after a 10 minute warmup time | |
ROHS compliant | RoHS II directive 2011/65/EU, EN50581:2012 | |
Display rate | 3 readings per second | |
Barometric Accuracy (Built-in barometer) | 50Pa | |
IP protection Level | IP67, 1 meter drop test | |
Communication | Isolate USB-TYPEC (slVe), Bluetooth BLE | |
Calibration | ISO 17025 accredited calibration with data |
Temperature Specification | ||||||||
---|---|---|---|---|---|---|---|---|
Thermocouple measurement and Source Accuracy | ||||||||
ADT227 | ADT227Ex | |||||||
Type | Standard | Temperature Range (°C) | Accuracy (°C) | Standard | Temperature Range (°C) | Accuracy (°C) | ||
measure / Source | measure / Source | |||||||
S | IEC 584 | -50 to 1768 | -50~0 | 0.76 | IEC 584 | -50 to 1768 | -50~100 | 0.77 |
0~100 | 0.56 | 100~1000 | 0.42 | |||||
100~1768 | 0.44 | 1000~1768 | 0.47 | |||||
R | IEC 584 | -50 to 1768 | -50~0 | 0.82 | IEC 584 | -50 to 1768 | -50~0 | 0.82 |
0~200 | 0.57 | 0~200 | 0.57 | |||||
200~1768 | 0.38 | 200~1768 | 0.42 | |||||
B | IEC 584 | 0 to 1820 | 200~300 | 1.51 | IEC 584 | 0 to 1820 | 200~300 | 1.51 |
300~500 | 1 | 300~500 | 1 | |||||
500~800 | 0.62 | 500~800 | 0.62 | |||||
800~1820 | 0.43 | 800~1820 | 0.43 | |||||
K | IEC 584 | -270 to 1372 | -250 to -200 | 0.72 | IEC 584 | -270 to 1372 | -250 to -200 | 0.75 |
-200 to -100 | 0.23 | -200 to -100 | 0.24 | |||||
-100 to 600 | 0.12 | -100 to 600 | 0.13 | |||||
600 to 1372 | 0.22 | 600 to 1372 | 0.25 | |||||
N | IEC 584 | -270 to 1300 | -250 to -200 | 1.14 | IEC 584 | -270 to 1300 | -250 to -200 | 1.17 |
-200 to -100 | 0.33 | -200 to -100 | 0.34 | |||||
-100 to 1300 | 0.19 | -100 to 1300 | 0.22 | |||||
E | IEC 584 | -270 to 1000 | -250~-200 | 0.39 | IEC 584 | -270 to 1000 | -250~-200 | 0.41 |
-200~-100 | 0.15 | -200~-100 | 0.15 | |||||
-100~700 | 0.09 | -100~700 | 0.1 | |||||
700~1000 | 0.12 | 700~1000 | 0.14 | |||||
J | IEC 584 | -210~1200 | -210~-100 | 0.19 | IEC 584 | -210~1200 | -210~-100 | 0.2 |
-100~700 | 0.1 | -100~700 | 0.11 | |||||
700~1200 | 0.15 | 700~1200 | 0.17 | |||||
T | IEC 584 | -270 to 400 | -250~-100 | 0.55 | IEC 584 | -270 to 400 | -250~-100 | 0.57 |
-100~0 | 0.12 | -100~0 | 0.23 | |||||
0~400 | 0.08 | 0~400 | 0.08 | |||||
C | ASTmE988 | 0 to 2315 | 0 to 1000 | 0.24 | ASTmE988 | 0 to 2315 | 0 to 1000 | 0.26 |
1000 to 1800 | 0.4 | 1000 to 1800 | 0.45 | |||||
1800 to 2315 | 0.65 | 1800 to 2315 | 0.73 | |||||
D | ASTmE988 | 0~2315 | 0~100 | 0.31 | ASTmE988 | 0~2315 | 0~100 | 0.31 |
100~1200 | 0.25 | 100~1200 | 0.27 | |||||
1200~2000 | 0.42 | 1200~2000 | 0.47 | |||||
2000~2315 | 0.65 | 2000~2315 | 0.74 | |||||
G | ASTmE1751 | 0 to 2315 | 50~100 | 0.9 | ASTmE1751 | 0 to 2315 | 50~100 | 0.9 |
100~200 | 0.57 | 100~200 | 0.57 | |||||
200~400 | 0.35 | 200~400 | 0.36 | |||||
400~1500 | 0.25 | 400~1500 | 0.27 | |||||
1500~2315 | 0.49 | 1500~2315 | 0.55 | |||||
L | DIN43710 | -200 to 900 | -200 to -100 | 0.11 | DIN43710 | -200 to 900 | -200 to -100 | 0.12 |
-100 to 400 | 0.08 | -100 to 400 | 0.09 | |||||
400o 900 | 0.1 | 400o 900 | 0.12 | |||||
U | DIN43710 | -200 to 600 | -200 to 0 | 0.21 | DIN43710 | -200 to 600 | -200 to 0 | 0.21 |
0 to 600 | 0.08 | 0 to 600 | 0.09 | |||||
Note: Internal CJC is ±0.15°C (-10°C to 50°C ambient Temperature) | ||||||||
Accuracy with external cold junction only, for internal cold junction add 0.15 ?(k=2) |
RTD measurement and Source Accuracy | ||||
---|---|---|---|---|
measure and simulate | Temperature Range (°C) | Accuracy (°C) | ||
ADT227 | ADT227Ex | |||
PT10(385) | -200 to 850 | -200~200 | 0.57 | 0.59 |
200~600 | 0.67 | 0.72 | ||
600~850 | 0.75 | 0.82 | ||
PT25(385) | -200 to 850 | -200~200 | 0.24 | 0.27 |
200~600 | 0.3 | 0.35 | ||
600~850 | 0.34 | 0.41 | ||
PT50(3916) | -200 to 850 | -200~200 | 0.13 | 0.16 |
200~600 | 0.17 | 0.22 | ||
600~850 | 0.2 | 0.27 | ||
PT100(385) PT100(391) PT100(3916) PT100(3926) | -200 to 850 | -200~200 | 0.08 | 0.1 |
200~600 | 0.11 | 0.16 | ||
600~850 | 0.14 | 0.2 | ||
PT200(385) | -200 to 850 | -200~200 | 0.32 | 0.08 |
200~300 | 0.34 | 0.34 | ||
300~600 | 0.41 | 0.41 | ||
600~850 | 0.48 | 0.48 | ||
PT400(385) | -200 to 850 | -200~0 | 0.15 | 0.04 |
0~200 | 0.18 | 0.18 | ||
200~600 | 0.25 | 0.25 | ||
600~850 | 0.3 | 0.3 | ||
PT500(385) | -200 to 850 | -200~200 | 0.16 | 0.16 |
200~600 | 0.22 | 0.22 | ||
600~850 | 0.27 | 0.27 | ||
PT1000(385) | -200 to 850 | -200~200 | 0.1 | 0.1 |
200~600 | 0.16 | 0.16 | ||
600~850 | 0.2 | 0.2 | ||
Cu10(427) | -200~260 | -200~260 | 0.54 | 0.56 |
Cu50(428) | -200~260 | -200~260 | 0.11 | 0.13 |
Cu100(428) | -200~260 | -200~260 | 0.07 | 0.08 |
Ni100(617) Ni100(618) | -60~180 | -60~0 | 0.05 | 0.06 |
0~180 | 0.05 | 0.05 | ||
Ni120(672) | -80~260 | -80~260 | 0.04 | 0.05 |
Ni1000 | -50~150 | -50~150 | 0.07 | 0.07 |